CTRON-SFPS-ESYS-MIB :: sfpsSysConfigSwitchMode

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-ESYS-MIB › sfpsSysConfigSwitchMode

sfpsSysConfigSwitchMode

Module: CTRON-SFPS-ESYS-MIB

OID (symbolic): CTRON-SFPS-ESYS-MIB::sfpsSysConfigSwitchMode

OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.20

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Displays the mode that the switch is running.

What is sfpsSysConfigSwitchMode?

Read-write selector for the switching mode of this instance -- vNET or vLAN mode, or one of the ATM NetWork/anNVL modes (aNVLLobo/aNVLFrontEnd) -- which determines how the SFPS engine forwards traffic between virtual networks or LAN emulation domains.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.20
snmpwalk -v2c -c public <target> CTRON-SFPS-ESYS-MIB::sfpsSysConfigSwitchMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.20.1
snmpget -v2c -c public <target> CTRON-SFPS-ESYS-MIB::sfpsSysConfigSwitchMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.20.1 i <value>

Start monitoring Cabletron SecureFast Packet Switch (SFPS), external system integration with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-ESYS-MIB::sfpsSysConfigSwitchMode OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), external system integration from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.4ctronSwitchCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2switchSFPSCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.1sfpsSwitchEngineCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.1.1sfpsSwitchSystemCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.1.1.1sfpsSystemConfigCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.4.2.1.1.1.1sfpsSysConfigTableCTRON-SFPS-ESYS-MIB
1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1sfpsSysConfigEntryCTRON-SFPS-ESYS-MIB
1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.20sfpsSysConfigSwitchModeCTRON-SFPS-ESYS-MIB