All MIBs › CTRON-SFPS-ESYS-MIB › sfpsSysConfigMgmtAccessType
sfpsSysConfigMgmtAccessType
Module: CTRON-SFPS-ESYS-MIB
OID (symbolic): CTRON-SFPS-ESYS-MIB::sfpsSysConfigMgmtAccessType
OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.22
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Determines whether the port can be used for management only or to be also used as an Access port.
What is sfpsSysConfigMgmtAccessType?
Read-write setting that controls whether the management port is restricted to management traffic only (mgmt-Only) or can also carry regular access-port traffic (mgmt-and-Access), letting an admin decide whether to dedicate that port purely to out-of-band management.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.22 snmpwalk -v2c -c public <target> CTRON-SFPS-ESYS-MIB::sfpsSysConfigMgmtAccessType
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.22.1 snmpget -v2c -c public <target> CTRON-SFPS-ESYS-MIB::sfpsSysConfigMgmtAccessType.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.22.1 i <value>
Start monitoring Cabletron SecureFast Packet Switch (SFPS), external system integration with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-ESYS-MIB::sfpsSysConfigMgmtAccessType OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), external system integration from a single console.
OID Breakdown
Upper-level ancestors (14 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.4 | ctronSwitch | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2 | switchSFPS | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1 | sfpsSwitchEngine | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.1 | sfpsSwitchSystem | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.1.1 | sfpsSystemConfig | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1 | sfpsSysConfigTable | CTRON-SFPS-ESYS-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1 | sfpsSysConfigEntry | CTRON-SFPS-ESYS-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.22 | sfpsSysConfigMgmtAccessType | CTRON-SFPS-ESYS-MIB |