All MIBs › CTRON-SFPS-ESYS-MIB › sfpsSysConfigHostDataPort
sfpsSysConfigHostDataPort
Module: CTRON-SFPS-ESYS-MIB
OID (symbolic): CTRON-SFPS-ESYS-MIB::sfpsSysConfigHostDataPort
OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.11
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
What is sfpsSysConfigHostDataPort?
The DESCRIPTION is empty in the source MIB, so this reading is inferred from the object name and type: it appears to report the logical port number used for host data traffic, paired with the Host Management (sfpsSysConfigHostMgmtPort) and Host Control (sfpsSysConfigHostCtrlPort) ports on the same switch instance.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.11 snmpwalk -v2c -c public <target> CTRON-SFPS-ESYS-MIB::sfpsSysConfigHostDataPort
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.11.1 snmpget -v2c -c public <target> CTRON-SFPS-ESYS-MIB::sfpsSysConfigHostDataPort.1
Start monitoring Cabletron SecureFast Packet Switch (SFPS), external system integration with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-ESYS-MIB::sfpsSysConfigHostDataPort OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), external system integration from a single console.
OID Breakdown
Upper-level ancestors (14 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.4 | ctronSwitch | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2 | switchSFPS | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1 | sfpsSwitchEngine | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.1 | sfpsSwitchSystem | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.1.1 | sfpsSystemConfig | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1 | sfpsSysConfigTable | CTRON-SFPS-ESYS-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1 | sfpsSysConfigEntry | CTRON-SFPS-ESYS-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.11 | sfpsSysConfigHostDataPort | CTRON-SFPS-ESYS-MIB |