All MIBs › CTRON-SFPS-ESYS-MIB › sfpsSysConfigHostCtrlPort
sfpsSysConfigHostCtrlPort
Module: CTRON-SFPS-ESYS-MIB
OID (symbolic): CTRON-SFPS-ESYS-MIB::sfpsSysConfigHostCtrlPort
OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.10
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Displays the logical port number for the Host Control Port. The Host Control Port is the port that unknown packets are sent to for call processing.
What is sfpsSysConfigHostCtrlPort?
Read-only logical port number of the Host Control Port -- the internal port the switch forwards unrecognized/unknown packets to so the host CPU can handle call setup processing for them.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.10 snmpwalk -v2c -c public <target> CTRON-SFPS-ESYS-MIB::sfpsSysConfigHostCtrlPort
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.10.1 snmpget -v2c -c public <target> CTRON-SFPS-ESYS-MIB::sfpsSysConfigHostCtrlPort.1
Start monitoring Cabletron SecureFast Packet Switch (SFPS), external system integration with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-ESYS-MIB::sfpsSysConfigHostCtrlPort OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), external system integration from a single console.
OID Breakdown
Upper-level ancestors (14 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.4 | ctronSwitch | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2 | switchSFPS | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1 | sfpsSwitchEngine | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.1 | sfpsSwitchSystem | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.1.1 | sfpsSystemConfig | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1 | sfpsSysConfigTable | CTRON-SFPS-ESYS-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1 | sfpsSysConfigEntry | CTRON-SFPS-ESYS-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.10 | sfpsSysConfigHostCtrlPort | CTRON-SFPS-ESYS-MIB |