All MIBs › CTRON-SFPS-DIRECTORY-MIB › sfpsTopologyDirStatsMaxLocalNodes
sfpsTopologyDirStatsMaxLocalNodes
Module: CTRON-SFPS-DIRECTORY-MIB
OID (symbolic): CTRON-SFPS-DIRECTORY-MIB::sfpsTopologyDirStatsMaxLocalNodes
OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.2.3.11.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The maximum number of local nodes that resided in Directory since the switch initiated.
What is sfpsTopologyDirStatsMaxLocalNodes?
The high-water mark for the number of local nodes that has resided in the directory since the switch was last initialized (i.e. since boot/restart). It's useful for capacity planning - if this is close to the switch's rated local-node limit, the directory is running near its design ceiling.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.11.7 snmpwalk -v2c -c public <target> CTRON-SFPS-DIRECTORY-MIB::sfpsTopologyDirStatsMaxLocalNodes
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.11.7.1 snmpget -v2c -c public <target> CTRON-SFPS-DIRECTORY-MIB::sfpsTopologyDirStatsMaxLocalNodes.1
Start monitoring Cabletron SecureFast Packet Switch (SFPS), end-station directory with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-DIRECTORY-MIB::sfpsTopologyDirStatsMaxLocalNodes OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), end-station directory from a single console.
OID Breakdown
Upper-level ancestors (14 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.4 | ctronSwitch | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2 | switchSFPS | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2 | sfpsSwitchAgent | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2.3 | sfpsAgentTopology | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2.3.11 | sfpsTopologyDirStats | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.4.2.2.3.11.7 | sfpsTopologyDirStatsMaxLocalNodes | CTRON-SFPS-DIRECTORY-MIB |