CTRON-SFPS-DIRECTORY-MIB :: sfpsServiceCenterDirectoryAdminStatus

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-DIRECTORY-MIB › sfpsServiceCenterDirectoryAdminStatus

sfpsServiceCenterDirectoryAdminStatus

Module: CTRON-SFPS-DIRECTORY-MIB

OID (symbolic): CTRON-SFPS-DIRECTORY-MIB::sfpsServiceCenterDirectoryAdminStatus

OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.2.2.4.3.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Administrative State of Entry.

What is sfpsServiceCenterDirectoryAdminStatus?

The administrative state requested for this directory server: other(1) for not running/stopped, disable(2) to request it stop, or enable(3) to request it run. Set this to control whether the server should be active; compare it against sfpsServiceCenterDirectoryOperStatus to confirm the request actually took effect.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.2.4.3.1.5
snmpwalk -v2c -c public <target> CTRON-SFPS-DIRECTORY-MIB::sfpsServiceCenterDirectoryAdminStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.2.4.3.1.5.1
snmpget -v2c -c public <target> CTRON-SFPS-DIRECTORY-MIB::sfpsServiceCenterDirectoryAdminStatus.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.4.2.2.2.4.3.1.5.1 i <value>

Start monitoring Cabletron SecureFast Packet Switch (SFPS), end-station directory with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-DIRECTORY-MIB::sfpsServiceCenterDirectoryAdminStatus OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), end-station directory from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.4ctronSwitchCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2switchSFPSCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2sfpsSwitchAgentCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.2sfpsAgentRedirectorCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.2.4sfpsServiceCenterCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.4.2.2.2.4.3sfpsServiceCenterDirectoryTableCTRON-SFPS-DIRECTORY-MIB
1.3.6.1.4.1.52.4.2.4.2.2.2.4.3.1sfpsServiceCenterDirectoryEntryCTRON-SFPS-DIRECTORY-MIB
1.3.6.1.4.1.52.4.2.4.2.2.2.4.3.1.5sfpsServiceCenterDirectoryAdminStatusCTRON-SFPS-DIRECTORY-MIB