All MIBs › CTRON-SFPS-DIRECTORY-MIB › sfpsDAPIVerb
sfpsDAPIVerb
Module: CTRON-SFPS-DIRECTORY-MIB
OID (symbolic): CTRON-SFPS-DIRECTORY-MIB::sfpsDAPIVerb
OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.2.3.10.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Describes the action to perform with the information provided in the other leafs of this MIB group. This leaf should be set last (after all other desired information is provided).
What is sfpsDAPIVerb?
A read-write control leaf describing the directory action to perform: add, delete, clearPort, clearPortLocals, clearSwitchRefs, lockNode, unlockNode, restrictPort, unrestrictPort, ageNodes, or ageAliases. This is the production equivalent of sfpsDAPITestVerb and must be set last, after the other sfpsDAPI* leaves (port, node type/value, alias type/value, age) have been populated with the arguments the chosen action needs.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.10.1 snmpwalk -v2c -c public <target> CTRON-SFPS-DIRECTORY-MIB::sfpsDAPIVerb
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.10.1.1 snmpget -v2c -c public <target> CTRON-SFPS-DIRECTORY-MIB::sfpsDAPIVerb.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.10.1.1 i <value>
Start monitoring Cabletron SecureFast Packet Switch (SFPS), end-station directory with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-DIRECTORY-MIB::sfpsDAPIVerb OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), end-station directory from a single console.
OID Breakdown
Upper-level ancestors (14 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.4 | ctronSwitch | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2 | switchSFPS | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2 | sfpsSwitchAgent | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2.3 | sfpsAgentTopology | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2.3.10 | sfpsTopologyDAPI | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.4.2.2.3.10.1 | sfpsDAPIVerb | CTRON-SFPS-DIRECTORY-MIB |