All MIBs › CTRON-SFPS-CONNECTION-MIB › sfpsConnectionSecOutPort
sfpsConnectionSecOutPort
Module: CTRON-SFPS-CONNECTION-MIB
OID (symbolic): CTRON-SFPS-CONNECTION-MIB::sfpsConnectionSecOutPort
OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.1.3.1.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Identifies the secondary outbound SFPS switch port. All switched traffic for this connection will be transmitted on this outbound port.
What is sfpsConnectionSecOutPort?
Identifies the secondary (backup) outbound switch port for this connection; switched traffic falls back to this port if the primary outbound port (sfpsConnectionPrimOutPort) can't be used.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.3.1.1.6 snmpwalk -v2c -c public <target> CTRON-SFPS-CONNECTION-MIB::sfpsConnectionSecOutPort
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.3.1.1.6.1 snmpget -v2c -c public <target> CTRON-SFPS-CONNECTION-MIB::sfpsConnectionSecOutPort.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sfpsConnectionSecOutPort.1
Start monitoring Cabletron SecureFast Packet Switch (SFPS), switched connections with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-CONNECTION-MIB::sfpsConnectionSecOutPort OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), switched connections from a single console.
OID Breakdown
Upper-level ancestors (13 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.4 | ctronSwitch | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2 | switchSFPS | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1 | sfpsSwitchEngine | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.3 | sfpsSwitchConnections | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.4.2.1.3.1 | sfpsConnectionTable | CTRON-SFPS-CONNECTION-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.3.1.1 | sfpsConnectionEntry | CTRON-SFPS-CONNECTION-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.3.1.1.6 | sfpsConnectionSecOutPort | CTRON-SFPS-CONNECTION-MIB |