CTRON-SFPS-CONNECTION-MIB :: sfpsConnectionSecOutPort

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-CONNECTION-MIB › sfpsConnectionSecOutPort

sfpsConnectionSecOutPort

Module: CTRON-SFPS-CONNECTION-MIB

OID (symbolic): CTRON-SFPS-CONNECTION-MIB::sfpsConnectionSecOutPort

OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.1.3.1.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Identifies the secondary outbound SFPS switch port. All switched traffic for this connection will be transmitted on this outbound port.

What is sfpsConnectionSecOutPort?

Identifies the secondary (backup) outbound switch port for this connection; switched traffic falls back to this port if the primary outbound port (sfpsConnectionPrimOutPort) can't be used.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.3.1.1.6
snmpwalk -v2c -c public <target> CTRON-SFPS-CONNECTION-MIB::sfpsConnectionSecOutPort

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.3.1.1.6.1
snmpget -v2c -c public <target> CTRON-SFPS-CONNECTION-MIB::sfpsConnectionSecOutPort.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sfpsConnectionSecOutPort.1

Start monitoring Cabletron SecureFast Packet Switch (SFPS), switched connections with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-CONNECTION-MIB::sfpsConnectionSecOutPort OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), switched connections from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.4ctronSwitchCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2switchSFPSCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.1sfpsSwitchEngineCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.1.3sfpsSwitchConnectionsCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.4.2.1.3.1sfpsConnectionTableCTRON-SFPS-CONNECTION-MIB
1.3.6.1.4.1.52.4.2.4.2.1.3.1.1sfpsConnectionEntryCTRON-SFPS-CONNECTION-MIB
1.3.6.1.4.1.52.4.2.4.2.1.3.1.1.6sfpsConnectionSecOutPortCTRON-SFPS-CONNECTION-MIB