CTRON-SFPS-CONNECTION-MIB :: sfpsConnectionConfigAPICnxHiMark

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-CONNECTION-MIB › sfpsConnectionConfigAPICnxHiMark

sfpsConnectionConfigAPICnxHiMark

Module: CTRON-SFPS-CONNECTION-MIB

OID (symbolic): CTRON-SFPS-CONNECTION-MIB::sfpsConnectionConfigAPICnxHiMark

OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.1.3.3.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Specifies the percentage of the Connection Table needed to be full before beginning aging.

What is sfpsConnectionConfigAPICnxHiMark?

Sets the percentage full the connection table must reach before the switch begins automatically aging out entries to reclaim space, defaulting to 95%.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.3.3.2
snmpwalk -v2c -c public <target> CTRON-SFPS-CONNECTION-MIB::sfpsConnectionConfigAPICnxHiMark

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.3.3.2.1
snmpget -v2c -c public <target> CTRON-SFPS-CONNECTION-MIB::sfpsConnectionConfigAPICnxHiMark.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.4.2.1.3.3.2.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sfpsConnectionConfigAPICnxHiMark.1

Start monitoring Cabletron SecureFast Packet Switch (SFPS), switched connections with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-CONNECTION-MIB::sfpsConnectionConfigAPICnxHiMark OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), switched connections from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.4ctronSwitchCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2switchSFPSCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.1sfpsSwitchEngineCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.1.3sfpsSwitchConnectionsCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.1.3.3sfpsConnectionConfigAPICTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.4.2.1.3.3.2sfpsConnectionConfigAPICnxHiMarkCTRON-SFPS-CONNECTION-MIB