CTRON-SFPS-BASE-MIB :: sfpsCPResourcesTablePtsUsed

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-BASE-MIB › sfpsCPResourcesTablePtsUsed

sfpsCPResourcesTablePtsUsed

Module: CTRON-SFPS-BASE-MIB

OID (symbolic): CTRON-SFPS-BASE-MIB::sfpsCPResourcesTablePtsUsed

OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.2.2.3.1.1.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The number of packets that have been sent to this Call Processor and accepted for the purpose of processing.

What is sfpsCPResourcesTablePtsUsed?

A running count of packets sent to this Call Processor that were accepted and actually processed, as opposed to dropped or rejected. Together with sfpsCPResourcesTablePtsIn, this lets an admin estimate the call processor's accept rate.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.2.3.1.1.7
snmpwalk -v2c -c public <target> CTRON-SFPS-BASE-MIB::sfpsCPResourcesTablePtsUsed

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.2.3.1.1.7.1
snmpget -v2c -c public <target> CTRON-SFPS-BASE-MIB::sfpsCPResourcesTablePtsUsed.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sfpsCPResourcesTablePtsUsed.1

Start monitoring Cabletron SecureFast Packet Switch (SFPS) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-BASE-MIB::sfpsCPResourcesTablePtsUsed OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS) from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.4ctronSwitchCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2switchSFPSCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2sfpsSwitchAgentCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.2sfpsAgentRedirectorCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.2.3sfpsCPResourcesCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.4.2.2.2.3.1sfpsCPResourcesTableCTRON-SFPS-BASE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.2.3.1.1sfpsCPResourcesTableEntryCTRON-SFPS-BASE-MIB