All MIBs › CTRON-SFPS-BASE-MIB › sfpsBlockSourceExcludeBlockFlag
sfpsBlockSourceExcludeBlockFlag
Module: CTRON-SFPS-BASE-MIB
OID (symbolic): CTRON-SFPS-BASE-MIB::sfpsBlockSourceExcludeBlockFlag
OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.2.14.5.1.1.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Describes whether the node is blocked or not. There are three possible integer values for this field: 0-notBlocked, 1-Blocked, 2-WouldBeBlocked. The WouldBeBlocked value is used to represent a node that would be in the blocked state if the SourceBlocker was enabled. A node can get into this state only if the blocker is disabled. If the blocker is enabled at this point, the node will be blocked, and a connection filter will be put in place when the next packet is received from this node
What is sfpsBlockSourceExcludeBlockFlag?
Reports the hypothetical blocked state of this excluded node: 0 notBlocked, 1 Blocked, or 2 WouldBeBlocked. Because the node is excluded, an admin would expect this to typically read WouldBeBlocked rather than an enforced Blocked state.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.14.5.1.1.7 snmpwalk -v2c -c public <target> CTRON-SFPS-BASE-MIB::sfpsBlockSourceExcludeBlockFlag
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.14.5.1.1.7.1 snmpget -v2c -c public <target> CTRON-SFPS-BASE-MIB::sfpsBlockSourceExcludeBlockFlag.1
Start monitoring Cabletron SecureFast Packet Switch (SFPS) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-BASE-MIB::sfpsBlockSourceExcludeBlockFlag OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS) from a single console.
OID Breakdown
Upper-level ancestors (14 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.4 | ctronSwitch | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2 | switchSFPS | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2 | sfpsSwitchAgent | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2.14 | sfpsSourceBlock | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2.14.5 | sfpsBlockSourceExclude | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.4.2.2.14.5.1 | sfpsBlockSourceExcludeTable | CTRON-SFPS-BASE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2.14.5.1.1 | sfpsBlockSourceExcludeEntry | CTRON-SFPS-BASE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2.14.5.1.1.7 | sfpsBlockSourceExcludeBlockFlag | CTRON-SFPS-BASE-MIB |