CTRON-REMOTE-ACCESS-MIB :: ctRemPhysAlarmTimeOut

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-REMOTE-ACCESS-MIB › ctRemPhysAlarmTimeOut

ctRemPhysAlarmTimeOut

Module: CTRON-REMOTE-ACCESS-MIB

OID (symbolic): CTRON-REMOTE-ACCESS-MIB::ctRemPhysAlarmTimeOut

OID (numeric): 1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.9

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Whenever the physical port is configured for nailed-up PPP this object specifies the time the physical port must remain in a failed state as a condition to begin the backup procedure. The backup procedure is begun for any active interface(s) that were connected over the failed physical port and which have been configured for backup.

What is ctRemPhysAlarmTimeOut?

For a physical port configured as nailed-up PPP, the number of seconds the port must stay in a failed state before the device starts its backup procedure for any active interfaces configured to fail over.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.9
snmpwalk -v2c -c public <target> CTRON-REMOTE-ACCESS-MIB::ctRemPhysAlarmTimeOut

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.9.1
snmpget -v2c -c public <target> CTRON-REMOTE-ACCESS-MIB::ctRemPhysAlarmTimeOut.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.9.1 i <value>

Start monitoring Cabletron/Enterasys remote-access server (dial-in/ISDN) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-REMOTE-ACCESS-MIB::ctRemPhysAlarmTimeOut OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys remote-access server (dial-in/ISDN) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.1ctronCTRON-ISDN-CONFIGURATION-MIB
1.3.6.1.4.1.52.4.1.2ctDataLinkCTRON-ISDN-CONFIGURATION-MIB
1.3.6.1.4.1.52.4.1.2.7ctronWanCTRON-ISDN-CONFIGURATION-MIB
1.3.6.1.4.1.52.4.1.2.7.2ctRemoteAccessCTRON-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.52.4.1.2.7.2.1ctRemoteConnectionCTRON-REMOTE-ACCESS-MIB
1.3.6.1.4.1.52.4.1.2.7.2.1.2ctRemPhysPortTableCTRON-REMOTE-ACCESS-MIB
1.3.6.1.4.1.52.4.1.2.7.2.1.2.1ctRemPhysPortEntryCTRON-REMOTE-ACCESS-MIB
1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.9ctRemPhysAlarmTimeOutCTRON-REMOTE-ACCESS-MIB