CTRON-REMOTE-ACCESS-MIB :: ctRemExtPhysPortProtMgrEnable

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-REMOTE-ACCESS-MIB › ctRemExtPhysPortProtMgrEnable

ctRemExtPhysPortProtMgrEnable

Module: CTRON-REMOTE-ACCESS-MIB

OID (symbolic): CTRON-REMOTE-ACCESS-MIB::ctRemExtPhysPortProtMgrEnable

OID (numeric): 1.3.6.1.4.1.52.4.1.2.7.2.1.6.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This object identifies an instance of the the enable flag of Protocol Manager residing on this physical port.

What is ctRemExtPhysPortProtMgrEnable?

Enables or disables this particular Protocol Manager instance on the physical port, letting an admin activate or deactivate one of several configured managers without deleting its configuration.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.2.7.2.1.6.1.4
snmpwalk -v2c -c public <target> CTRON-REMOTE-ACCESS-MIB::ctRemExtPhysPortProtMgrEnable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.2.7.2.1.6.1.4.1
snmpget -v2c -c public <target> CTRON-REMOTE-ACCESS-MIB::ctRemExtPhysPortProtMgrEnable.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.1.2.7.2.1.6.1.4.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> ctRemExtPhysPortProtMgrEnable.1

Start monitoring Cabletron/Enterasys remote-access server (dial-in/ISDN) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-REMOTE-ACCESS-MIB::ctRemExtPhysPortProtMgrEnable OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys remote-access server (dial-in/ISDN) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.1ctronCTRON-ISDN-CONFIGURATION-MIB
1.3.6.1.4.1.52.4.1.2ctDataLinkCTRON-ISDN-CONFIGURATION-MIB
1.3.6.1.4.1.52.4.1.2.7ctronWanCTRON-ISDN-CONFIGURATION-MIB
1.3.6.1.4.1.52.4.1.2.7.2ctRemoteAccessCTRON-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.52.4.1.2.7.2.1ctRemoteConnectionCTRON-REMOTE-ACCESS-MIB
1.3.6.1.4.1.52.4.1.2.7.2.1.6ctRemExtPhysPortTableCTRON-REMOTE-ACCESS-MIB
1.3.6.1.4.1.52.4.1.2.7.2.1.6.1ctRemExtPhysPortEntryCTRON-REMOTE-ACCESS-MIB
1.3.6.1.4.1.52.4.1.2.7.2.1.6.1.4ctRemExtPhysPortProtMgrEnableCTRON-REMOTE-ACCESS-MIB