CTRON-REMOTE-ACCESS-MIB :: ctDs1ExtensionsCFADuration

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-REMOTE-ACCESS-MIB › ctDs1ExtensionsCFADuration

ctDs1ExtensionsCFADuration

Module: CTRON-REMOTE-ACCESS-MIB

OID (symbolic): CTRON-REMOTE-ACCESS-MIB::ctDs1ExtensionsCFADuration

OID (numeric): 1.3.6.1.4.1.52.4.1.2.7.2.2.1.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The length of time (in seconds), that the ds1 port will remain in the Carrier Failure Alarm state after the alarm condition has cleared. For those Ds1 ports not supporting Carrier Failure Alarm duration, this object always returns 1, and setting the object has no effect.

What is ctDs1ExtensionsCFADuration?

How many seconds (1-15) this DS1 port stays in the Carrier Failure Alarm state after the alarm condition clears, before declaring the carrier restored; ports without this feature always report 1 and ignore writes.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.2.7.2.2.1.1.5
snmpwalk -v2c -c public <target> CTRON-REMOTE-ACCESS-MIB::ctDs1ExtensionsCFADuration

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.2.7.2.2.1.1.5.1
snmpget -v2c -c public <target> CTRON-REMOTE-ACCESS-MIB::ctDs1ExtensionsCFADuration.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.1.2.7.2.2.1.1.5.1 i <value>

Start monitoring Cabletron/Enterasys remote-access server (dial-in/ISDN) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-REMOTE-ACCESS-MIB::ctDs1ExtensionsCFADuration OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys remote-access server (dial-in/ISDN) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.1ctronCTRON-ISDN-CONFIGURATION-MIB
1.3.6.1.4.1.52.4.1.2ctDataLinkCTRON-ISDN-CONFIGURATION-MIB
1.3.6.1.4.1.52.4.1.2.7ctronWanCTRON-ISDN-CONFIGURATION-MIB
1.3.6.1.4.1.52.4.1.2.7.2ctRemoteAccessCTRON-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.52.4.1.2.7.2.2ctDs1ExtCTRON-REMOTE-ACCESS-MIB
1.3.6.1.4.1.52.4.1.2.7.2.2.1ctDs1ExtensionsTableCTRON-REMOTE-ACCESS-MIB
1.3.6.1.4.1.52.4.1.2.7.2.2.1.1ctDs1ExtensionsEntryCTRON-REMOTE-ACCESS-MIB
1.3.6.1.4.1.52.4.1.2.7.2.2.1.1.5ctDs1ExtensionsCFADurationCTRON-REMOTE-ACCESS-MIB