All MIBs › CTRON-IF-REMAP-2-MIB › ctIFRemap2VlanStatus
ctIFRemap2VlanStatus
Module: CTRON-IF-REMAP-2-MIB
OID (symbolic): CTRON-IF-REMAP-2-MIB::ctIFRemap2VlanStatus
OID (numeric): 1.3.6.1.4.1.52.4.1.1.14.1.4.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Defines the status of the ifremap vlan entry. Setting ctIFRemap2VlanStatus to a value of enable(1) has the effect of creating an entry in the table when it does not already exist. Setting ctIFRemap2VlanStatus to a value of disable(2) disables the entry and deletes the row from the table. Therefore this table only contains entries that are active.
If ctIFRemap2VlanSourceVlan is already being used by another ctIfRemap2Vlan entry or ctifRemap2 Entry then a set to ctIFRemap2VlanStatus of value enable(1) will return with a BAD-VALUE error.
What is ctIFRemap2VlanStatus?
This value controls whether a VLAN-to-port ifremap row is active, with enable(1) creating the entry and disable(2) deleting it from the table. Because a given source VLAN can only be tied to one active remap relationship, enabling a row whose source VLAN is already used by another VLAN or port-based entry fails with a BAD-VALUE error. For example, if VLAN 35 is already remapped in one row, trying to enable(1) a second row also sourcing VLAN 35 is rejected until the first is disabled.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.14.1.4.1.5 snmpwalk -v2c -c public <target> CTRON-IF-REMAP-2-MIB::ctIFRemap2VlanStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.14.1.4.1.5.1 snmpget -v2c -c public <target> CTRON-IF-REMAP-2-MIB::ctIFRemap2VlanStatus.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.1.1.14.1.4.1.5.1 i <value>
Start monitoring Cabletron/Enterasys modular chassis switch (interface remap v2) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-IF-REMAP-2-MIB::ctIFRemap2VlanStatus OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys modular chassis switch (interface remap v2) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.1 | ctron | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.1.1 | ctPhysical | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.1.1.14 | ctIFRemap2 | CTRON-MIB-NAMES |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.1.1.14.1 | ctIFRemap2Config | CTRON-IF-REMAP-2-MIB |
| 1.3.6.1.4.1.52.4.1.1.14.1.4 | ctIFRemap2VlanTable | CTRON-IF-REMAP-2-MIB |
| 1.3.6.1.4.1.52.4.1.1.14.1.4.1 | ctIFRemap2VlanEntry | CTRON-IF-REMAP-2-MIB |
| 1.3.6.1.4.1.52.4.1.1.14.1.4.1.5 | ctIFRemap2VlanStatus | CTRON-IF-REMAP-2-MIB |