All MIBs › CTRON-IF-REMAP-2-MIB › ctIFRemap2PortReference
ctIFRemap2PortReference
Module: CTRON-IF-REMAP-2-MIB
OID (symbolic): CTRON-IF-REMAP-2-MIB::ctIFRemap2PortReference
OID (numeric): 1.3.6.1.4.1.52.4.1.1.14.1.2.1.3
Node type: OBJECT-TYPE
Type: OBJECT IDENTIFIER
Access: read-only
Description: This object returns an OID referencing an object which uniquely corresponds to this remap port. The only criteria is that this OID is a leaf, and that it exists and is accessible. For example, if remap functionality is running on an 802.1d compliant bridge, remap port #1 could reference dot1dBasePort.1. Alternatively you could reference a mib2 interface like ifIndex.1 or a Cabletron Secure Fast port. Mixing these types (some refer to bridge ports, others refer to SFS ports) is not advised, but not prohibited
What is ctIFRemap2PortReference?
This value returns the OID of another MIB object instance that uniquely identifies the real interface underlying this remap-capable port entry. Admins walk this to map a slot/port pair in ctIFRemap2PortTable back to a familiar object, such as a bridge port or an ifIndex entry, so they know which physical interface they are actually configuring for remap. For example, per the description's own guidance it might return dot1dBasePort.1 for a bridge port or ifIndex.1 for a standard MIB-II interface.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.14.1.2.1.3 snmpwalk -v2c -c public <target> CTRON-IF-REMAP-2-MIB::ctIFRemap2PortReference
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.14.1.2.1.3.1 snmpget -v2c -c public <target> CTRON-IF-REMAP-2-MIB::ctIFRemap2PortReference.1
Start monitoring Cabletron/Enterasys modular chassis switch (interface remap v2) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-IF-REMAP-2-MIB::ctIFRemap2PortReference OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys modular chassis switch (interface remap v2) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.1 | ctron | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.1.1 | ctPhysical | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.1.1.14 | ctIFRemap2 | CTRON-MIB-NAMES |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.1.1.14.1 | ctIFRemap2Config | CTRON-IF-REMAP-2-MIB |
| 1.3.6.1.4.1.52.4.1.1.14.1.2 | ctIFRemap2PortTable | CTRON-IF-REMAP-2-MIB |
| 1.3.6.1.4.1.52.4.1.1.14.1.2.1 | ctIFRemap2PortEntry | CTRON-IF-REMAP-2-MIB |
| 1.3.6.1.4.1.52.4.1.1.14.1.2.1.3 | ctIFRemap2PortReference | CTRON-IF-REMAP-2-MIB |