All MIBs › CTRON-IF-REMAP-2-MIB › ctIFRemap2PhysErrsCapable
ctIFRemap2PhysErrsCapable
Module: CTRON-IF-REMAP-2-MIB
OID (symbolic): CTRON-IF-REMAP-2-MIB::ctIFRemap2PhysErrsCapable
OID (numeric): 1.3.6.1.4.1.52.4.1.1.14.1.2.1.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Indicate whether the port is incapable of remapping physical errors. If the capability is supported, this object will return supported(1). If the capability is unsupported, this object will return unsupported(2).
What is ctIFRemap2PhysErrsCapable?
This value indicates whether this specific remap-capable port's hardware can remap frames that carry physical layer errors. It is a read-only capability flag that governs whether ctIFRemap2PhysicalErrors can actually be set on entries using this port, since that object is forced to unsupported whenever this one reads unsupported. For example, an older module might report unsupported(2) for its ports, so any remap entry sourced or destined there will have its physical-errors setting locked to unsupported.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.14.1.2.1.4 snmpwalk -v2c -c public <target> CTRON-IF-REMAP-2-MIB::ctIFRemap2PhysErrsCapable
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.14.1.2.1.4.1 snmpget -v2c -c public <target> CTRON-IF-REMAP-2-MIB::ctIFRemap2PhysErrsCapable.1
Start monitoring Cabletron/Enterasys modular chassis switch (interface remap v2) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-IF-REMAP-2-MIB::ctIFRemap2PhysErrsCapable OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys modular chassis switch (interface remap v2) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.1 | ctron | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.1.1 | ctPhysical | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.1.1.14 | ctIFRemap2 | CTRON-MIB-NAMES |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.1.1.14.1 | ctIFRemap2Config | CTRON-IF-REMAP-2-MIB |
| 1.3.6.1.4.1.52.4.1.1.14.1.2 | ctIFRemap2PortTable | CTRON-IF-REMAP-2-MIB |
| 1.3.6.1.4.1.52.4.1.1.14.1.2.1 | ctIFRemap2PortEntry | CTRON-IF-REMAP-2-MIB |
| 1.3.6.1.4.1.52.4.1.1.14.1.2.1.4 | ctIFRemap2PhysErrsCapable | CTRON-IF-REMAP-2-MIB |