All MIBs › CTRON-FDDI-FNB-MIB › ctFddiFPIM
ctFddiFPIM
Module: CTRON-FDDI-FNB-MIB
OID (symbolic): CTRON-FDDI-FNB-MIB::ctFddiFPIM
OID (numeric): 1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Defines the instance of the port for which this definition is made. Ports are physically located from top-to-bottom on a particular module. If there are multiple 'columns' of ports from the top to the bottom, then the numbering will start from the left side and proceed top-to-bottom in each column.
What is ctFddiFPIM?
This value identifies the specific FPIM port position on the module's front panel, numbered top-to-bottom and, where there are multiple columns, left-to-right by column. An admin uses it to physically map an SNMP-reported FPIM entry to the exact port position on the module's faceplate, helpful when tracing a specific connector during hands-on troubleshooting. For example, a ctFddiFPIM value of 3 on a single-column module would identify the third port from the top of that module's front panel.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.2 snmpwalk -v2c -c public <target> CTRON-FDDI-FNB-MIB::ctFddiFPIM
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.2.1 snmpget -v2c -c public <target> CTRON-FDDI-FNB-MIB::ctFddiFPIM.1
Start monitoring Cabletron FDDI concentrator/hub (FNB backplane) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-FDDI-FNB-MIB::ctFddiFPIM OID value, configure state conditions and alerts, and monitor any Cabletron FDDI concentrator/hub (FNB backplane) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.1 | ctron | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.1.2 | ctDataLink | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.1.2.5 | ctFDDI | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.1.2.5.1 | ctFDDIFnb | CTRON-MIB-NAMES |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.1.2.5.1.4 | ctFDDISerialConfig | CTRON-FDDI-FNB-MIB |
| 1.3.6.1.4.1.52.4.1.2.5.1.4.3 | ctFDDIModuleFPIMTable | CTRON-FDDI-FNB-MIB |
| 1.3.6.1.4.1.52.4.1.2.5.1.4.3.1 | ctFDDIModuleFPIMEntry | CTRON-FDDI-FNB-MIB |
| 1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.2 | ctFddiFPIM | CTRON-FDDI-FNB-MIB |