CTRON-FDDI-FNB-MIB :: ctFDDINMCapEnable

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-FDDI-FNB-MIB › ctFDDINMCapEnable

ctFDDINMCapEnable

Module: CTRON-FDDI-FNB-MIB

OID (symbolic): CTRON-FDDI-FNB-MIB::ctFDDINMCapEnable

OID (numeric): 1.3.6.1.4.1.52.4.1.2.5.1.2.2.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: A specific configuration that is enabled.

Enabling a configuration is done by writing the value of ctFDDINMConfigID for a specific configuration to this object.

This object, when read, will return the value of ctFDDINMConfigID for the presently enabled configuration.

What is ctFDDINMCapEnable?

This is a read-write field where writing a specific ctFDDINMConfigID value activates that connection configuration on the module, and reading it back reveals which configuration is currently active. It is the actual control lever an admin uses to remotely change a module's FNB wiring topology. For example, writing the value 2 here switches this module over to the dual counter-rotating ring configuration described by config ID 2's ctFDDINMConfigDesc.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.2.5.1.2.2.1.2
snmpwalk -v2c -c public <target> CTRON-FDDI-FNB-MIB::ctFDDINMCapEnable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.2.5.1.2.2.1.2.1
snmpget -v2c -c public <target> CTRON-FDDI-FNB-MIB::ctFDDINMCapEnable.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.1.2.5.1.2.2.1.2.1 i <value>

Start monitoring Cabletron FDDI concentrator/hub (FNB backplane) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-FDDI-FNB-MIB::ctFDDINMCapEnable OID value, configure state conditions and alerts, and monitor any Cabletron FDDI concentrator/hub (FNB backplane) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.1ctronCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.2ctDataLinkCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.2.5ctFDDICTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.2.5.1ctFDDIFnbCTRON-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.52.4.1.2.5.1.2ctFDDINonMuxCTRON-FDDI-FNB-MIB
1.3.6.1.4.1.52.4.1.2.5.1.2.2ctFDDINonMuxCapEnableTableCTRON-FDDI-FNB-MIB
1.3.6.1.4.1.52.4.1.2.5.1.2.2.1ctFDDINonMuxCapEnableEntryCTRON-FDDI-FNB-MIB
1.3.6.1.4.1.52.4.1.2.5.1.2.2.1.2ctFDDINMCapEnableCTRON-FDDI-FNB-MIB