All MIBs › CTRON-DCM-MIB › dCMMode
dCMMode
Module: CTRON-DCM-MIB
OID (symbolic): CTRON-DCM-MIB::dCMMode
OID (numeric): 1.3.6.1.4.1.52.4.1.6.1.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: A value which indicates whether this module supports a view chassis-wide of management information, accessed via chassis-ip. This MIB view is actually composed of information which is distributed between modules within the chassis but is able to be viewed as a collective whole. When a module is in standalone mode, it only supports original, module-level mibs. In distributed mode, the module will operate in conjunction with other distributed modules to share management information and present it to management clients through the chassis ip.
0 = STANDALONE 1 = DISTRIBUTED
What is dCMMode?
dCMMode is a read-write setting that determines whether this module operates in standalone mode, exposing only its own module-level MIBs, or in distributed mode, contributing to a chassis-wide management view reachable via a chassis IP address. An admin cares about this because it changes how the device must be polled: in standalone mode each module answers only for itself, while in distributed mode information from multiple modules is assembled into one collective chassis view. For example, switching dCMMode from standalone to distributed on a module makes it start contributing its data to the chassis-wide MIB view instead of only answering queries against its own local module address.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.6.1.1 snmpwalk -v2c -c public <target> CTRON-DCM-MIB::dCMMode
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.6.1.1.1 snmpget -v2c -c public <target> CTRON-DCM-MIB::dCMMode.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.1.6.1.1.1 i <value>
Start monitoring Cabletron Systems modular chassis/hub (Distributed Chassis Management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-DCM-MIB::dCMMode OID value, configure state conditions and alerts, and monitor any Cabletron Systems modular chassis/hub (Distributed Chassis Management) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.1 | ctron | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.1.6 | ctDcm | CTRON-MIB-NAMES |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.1.6.1 | dCM | CTRON-DCM-MIB |
| 1.3.6.1.4.1.52.4.1.6.1.1 | dCMMode | CTRON-DCM-MIB |