All MIBs › CTRON-CHASSIS-MIB › ctChasPowerSupplyRedundancy
ctChasPowerSupplyRedundancy
Module: CTRON-CHASSIS-MIB
OID (symbolic): CTRON-CHASSIS-MIB::ctChasPowerSupplyRedundancy
OID (numeric): 1.3.6.1.4.1.52.4.3.1.2.1.1.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Denotes whether or not the power supply is redundant.
What is ctChasPowerSupplyRedundancy?
This read-only enumerated integer reports whether a specific power supply in the chassis is operating in a redundant(1) or notRedundant(2) configuration, or notSupported(3) if the chassis lacks redundancy capability. An administrator checks this to confirm a chassis is properly protected against a single power supply failure before considering it production-ready for critical infrastructure. For example, before deploying a chassis as a core switch, the admin verifies this object reads redundant(1) to ensure a single power supply failure won't bring down the device.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.3.1.2.1.1.4 snmpwalk -v2c -c public <target> CTRON-CHASSIS-MIB::ctChasPowerSupplyRedundancy
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.3.1.2.1.1.4.1 snmpget -v2c -c public <target> CTRON-CHASSIS-MIB::ctChasPowerSupplyRedundancy.1
Start monitoring Cabletron/Enterasys modular chassis switch (hardware inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-CHASSIS-MIB::ctChasPowerSupplyRedundancy OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys modular chassis switch (hardware inventory) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.3 | ctronExtn | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.3.1 | ctronChassis | CTRON-MIB-NAMES |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.3.1.2 | ctEnviron | CTRON-CHASSIS-MIB |
| 1.3.6.1.4.1.52.4.3.1.2.1 | ctChasPowerTable | CTRON-CHASSIS-MIB |
| 1.3.6.1.4.1.52.4.3.1.2.1.1 | ctChasPowerEntry | CTRON-CHASSIS-MIB |
| 1.3.6.1.4.1.52.4.3.1.2.1.1.4 | ctChasPowerSupplyRedundancy | CTRON-CHASSIS-MIB |