CTRON-BRIDGE-MIB :: ctBridgeBaseChassisMgr

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCTRON-BRIDGE-MIBctBridgeBaseChassisMgr

ctBridgeBaseChassisMgr

Module: CTRON-BRIDGE-MIB

OID (symbolic): CTRON-BRIDGE-MIB::ctBridgeBaseChassisMgr

OID (numeric): 1.3.6.1.4.1.52.4.1.2.3.8.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This object reports the chassis management capability of the bridging device. Chassis management is defined as the ability of the device to report status on MIM boards which the device might be responsible for managing, modifying the state of the MIM boards and the ports residing on the MIM board, and tracking and reporting on the status of the networks being bridged and the stations generating traffic on those networks. Note that this is not a comprehensive list of the activities which comprise chassis management.

If chassis management is unsupported by this device, then the value notSupported is returned. If chassis management is supported by this device and the device is, in fact, operating as a chassis manager, then the value managementEnabled is re- turned. If chassis management is supported by this device but the device is not functioning as a chassis manager, the value managementDisabled is returned.

What is ctBridgeBaseChassisMgr?

This read-only enumerated integer reports the chassis management capability of the bridging device: notSupported(1), managementDisabled(2), or managementEnabled(3), reflecting whether the device can report and control status of MIM boards and their ports and networks it is responsible for managing. An administrator checks this to determine whether a modular chassis-based bridge is actually configured to expose its internal board and port management functionality via this MIB. For example, before relying on this MIB to monitor individual line cards in a chassis, the admin first confirms this object reads managementEnabled(3) rather than managementDisabled(2).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.2.3.8.1
snmpwalk -v2c -c public <target> CTRON-BRIDGE-MIB::ctBridgeBaseChassisMgr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.2.3.8.1.1
snmpget -v2c -c public <target> CTRON-BRIDGE-MIB::ctBridgeBaseChassisMgr.1

Start monitoring Cabletron/Enterasys network switch (bridge/spanning tree) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-BRIDGE-MIB::ctBridgeBaseChassisMgr OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys network switch (bridge/spanning tree) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCTRON-AP3000-MIB
1.3.6.1.4.1.52.4.1ctronCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.2ctDataLinkCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.2.3ctBridgeCTRON-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.52.4.1.2.3.8ctBridgeExtendedControlCTRON-BRIDGE-MIB
1.3.6.1.4.1.52.4.1.2.3.8.1ctBridgeBaseChassisMgrCTRON-BRIDGE-MIB