CTATX-MIB :: configPowerPresent2

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCTATX-MIBconfigPowerPresent2

configPowerPresent2

Module: CTATX-MIB

OID (symbolic): CTATX-MIB::configPowerPresent2

OID (numeric): 1.3.6.1.4.1.97.3.3.1.11

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Whether the second power supply is present.

What is configPowerPresent2?

This read-only INTEGER reports whether the second power supply bay is physically populated, either supply-present(1) or supply-absent(2). An administrator checks it to confirm power redundancy is actually installed, not merely powered off. For example, a newly racked chassis reports configPowerPresent2 as supply-absent(2), alerting the installer that only one of the two supply bays was actually populated.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.97.3.3.1.11
snmpwalk -v2c -c public <target> CTATX-MIB::configPowerPresent2

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.97.3.3.1.11.1
snmpget -v2c -c public <target> CTATX-MIB::configPowerPresent2.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> configPowerPresent2.1

Start monitoring Cabletron/Enterasys ATX switch module with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTATX-MIB::configPowerPresent2 OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys ATX switch module from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.97sigmaCT-ELS10-27-MIB
Numeric OIDNameModule
1.3.6.1.4.1.97.3ecs_1CTATX-MIB
1.3.6.1.4.1.97.3.3adminCTATX-MIB
1.3.6.1.4.1.97.3.3.1configCTATX-MIB
1.3.6.1.4.1.97.3.3.1.11configPowerPresent2CTATX-MIB