Description: Whether the first power supply is present.
What is configPowerPresent1?
This read-only INTEGER reports whether the first power supply bay is physically populated, either supply-present(1) or supply-absent(2), independent of whether an installed supply is actually working. An administrator uses it to distinguish a missing supply from an installed-but-failed one reported by configPowerAc1/configPowerDc1. For example, configPowerPresent1 reads supply-absent(2) after a technician pulls supply 1 for bench testing, confirming the chassis correctly detects the empty bay.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.97.3.3.1.10 snmpwalk -v2c -c public <target> CTATX-MIB::configPowerPresent1
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.97.3.3.1.10.1 snmpget -v2c -c public <target> CTATX-MIB::configPowerPresent1.1
Start monitoring Cabletron/Enterasys ATX switch module with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTATX-MIB::configPowerPresent1 OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys ATX switch module from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.97 | sigma | CT-ELS10-27-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.97.3 | ecs_1 | CTATX-MIB |
| 1.3.6.1.4.1.97.3.3 | admin | CTATX-MIB |
| 1.3.6.1.4.1.97.3.3.1 | config | CTATX-MIB |
| 1.3.6.1.4.1.97.3.3.1.10 | configPowerPresent1 | CTATX-MIB |