All MIBs › CTATX-MIB › configPowerDc1
configPowerDc1
Module: CTATX-MIB
OID (symbolic): CTATX-MIB::configPowerDc1
OID (numeric): 1.3.6.1.4.1.97.3.3.1.8
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Whether the first power supply provides DC voltage.
What is configPowerDc1?
This read-only INTEGER reports whether the first power supply is producing good DC output, either dc-good(1) or dc-bad(2), which can fail independently of the AC feed reported by configPowerAc1. An administrator uses it to distinguish an internal supply failure from an external AC problem. For example, configPowerAc1 reads ac-good(1) but configPowerDc1 reads dc-bad(2), pointing to a failed internal conversion stage rather than a lost AC feed.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.97.3.3.1.8 snmpwalk -v2c -c public <target> CTATX-MIB::configPowerDc1
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.97.3.3.1.8.1 snmpget -v2c -c public <target> CTATX-MIB::configPowerDc1.1
Start monitoring Cabletron/Enterasys ATX switch module with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTATX-MIB::configPowerDc1 OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys ATX switch module from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.97 | sigma | CT-ELS10-27-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.97.3 | ecs_1 | CTATX-MIB |
| 1.3.6.1.4.1.97.3.3 | admin | CTATX-MIB |
| 1.3.6.1.4.1.97.3.3.1 | config | CTATX-MIB |
| 1.3.6.1.4.1.97.3.3.1.8 | configPowerDc1 | CTATX-MIB |