CTATX-MIB :: configPowerAc1

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCTATX-MIBconfigPowerAc1

configPowerAc1

Module: CTATX-MIB

OID (symbolic): CTATX-MIB::configPowerAc1

OID (numeric): 1.3.6.1.4.1.97.3.3.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Whether the first power supply has AC input.

What is configPowerAc1?

This read-only INTEGER reports whether the first power supply currently has AC input, either ac-good(1) or ac-bad(2). An administrator monitors it as an early warning of a failed AC feed to that supply before the supply itself fails outright. For example, during a planned test of failover, a technician disconnects the AC cord to supply 1 and confirms configPowerAc1 immediately flips to ac-bad(2).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.97.3.3.1.6
snmpwalk -v2c -c public <target> CTATX-MIB::configPowerAc1

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.97.3.3.1.6.1
snmpget -v2c -c public <target> CTATX-MIB::configPowerAc1.1

Start monitoring Cabletron/Enterasys ATX switch module with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTATX-MIB::configPowerAc1 OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys ATX switch module from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.97sigmaCT-ELS10-27-MIB
Numeric OIDNameModule
1.3.6.1.4.1.97.3ecs_1CTATX-MIB
1.3.6.1.4.1.97.3.3adminCTATX-MIB
1.3.6.1.4.1.97.3.3.1configCTATX-MIB
1.3.6.1.4.1.97.3.3.1.6configPowerAc1CTATX-MIB