CT-CHASSIS-MIB :: chCompMIBGrpOID

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CT-CHASSIS-MIB › chCompMIBGrpOID

chCompMIBGrpOID

Module: CT-CHASSIS-MIB

OID (symbolic): CT-CHASSIS-MIB::chCompMIBGrpOID

OID (numeric): 1.3.6.1.4.1.52.4.1.1.2.6.1.4

Node type: OBJECT-TYPE

Type: OBJECT IDENTIFIER

Access: read-write

Description: A reference to a specific MIB group definition. For example, in the case of MIB-II, the value of this object may refer to an applicable group, which has been implemented.

The access is read-write. This will allow network administrators, to register MIBs for a module that is known to the chassis management entity, by type alone: that is, a module for which component information is unknown.

What is chCompMIBGrpOID?

This read-write object identifier references a specific MIB group definition, such as a MIB-II group, that this registration entry corresponds to, and it is writable specifically so administrators can register MIBs for a module the chassis recognizes only by type. Network admins use this to manually associate a known module type with the MIB group it should expose, when the chassis can't auto-discover that mapping. For example, an admin adding support for a newly recognized module type might write the appropriate MIB group OID into chCompMIBGrpOID to formally register which management information that module type provides.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.2.6.1.4
snmpwalk -v2c -c public <target> CT-CHASSIS-MIB::chCompMIBGrpOID

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.2.6.1.4.1
snmpget -v2c -c public <target> CT-CHASSIS-MIB::chCompMIBGrpOID.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.1.1.2.6.1.4.1 s <value>

Start monitoring Cabletron Systems chassis-based hub/switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CT-CHASSIS-MIB::chCompMIBGrpOID OID value, configure state conditions and alerts, and monitor any Cabletron Systems chassis-based hub/switch from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCTRON-AP3000-MIB
1.3.6.1.4.1.52.4.1ctronCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.1ctPhysicalCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.1.2chassisCTRON-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.52.4.1.1.2.6chCompMIBTableCT-CHASSIS-MIB
1.3.6.1.4.1.52.4.1.1.2.6.1chCompMIBEntryCT-CHASSIS-MIB
1.3.6.1.4.1.52.4.1.1.2.6.1.4chCompMIBGrpOIDCT-CHASSIS-MIB