All MIBs › CSAT-5060 › csat5060MaintenanceParameters
csat5060MaintenanceParameters
Module: CSAT-5060
OID (symbolic): CSAT-5060::csat5060MaintenanceParameters
OID (numeric): 1.3.6.1.4.1.6247.29.1.6.2
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-only
Description: CSAT Concise Maintenance Parameters. (CMS?) CMS=aaa.abbb.bccc.cddd.deee.efff.fggg.ghhh.hiii.ijjj.jkkk.klll.lmmm.mnnn.nooo.oppp.p where: aaa.a = 24V Power Supply bbb.b = 20V Power Supply ccc.c = 12V Power Supply ddd.d = 10V Power Supply eee.e = +5V Power Supply fff.f = -5V Power Supply ggg.g = TX Synthesizer Tuning Voltage hhh.h = TX IFLO Tuning Voltage iii.i = RX Synthesizer Tuning Voltage jjj.j = RX IFLO Tuning Voltage kkk.k = Reference Tuning Voltage lll.l = LNA Current in milliamps mmm.m = Fan Current in milliamps nnn.n = Up Conv Heat Sink Temperature ooo.o = RF Output Power in dB ppp.p = Down Converter Temperature
Note: Value is xxx.x if not available
What is csat5060MaintenanceParameters?
This read-only string reports a concise set of internal maintenance telemetry values, retrieved via the CMS? command, packing multiple power-supply voltages such as 24V, 20V, 12V, 10V, plus 5V, and minus 5V, along with synthesizer and IFLO tuning voltages into one formatted response. Admins use this single field as a quick health snapshot of the unit's internal power and RF synthesis subsystems without querying each parameter individually. For example, an unusually low value parsed out of csat5060MaintenanceParameters for the 12V power supply reading could point an admin toward a failing power supply before it causes an outage.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6247.29.1.6.2 snmpwalk -v2c -c public <target> CSAT-5060::csat5060MaintenanceParameters
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6247.29.1.6.2.1 snmpget -v2c -c public <target> CSAT-5060::csat5060MaintenanceParameters.1
Start monitoring Comtech EF Data CSAT-5060 satellite transceiver with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CSAT-5060::csat5060MaintenanceParameters OID value, configure state conditions and alerts, and monitor any Comtech EF Data CSAT-5060 satellite transceiver from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6247 | comtechEFData | ComtechEFData |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6247.29 | csat5060 | CSAT-5060 |
| 1.3.6.1.4.1.6247.29.1 | csat5060Objects | CSAT-5060 |
| 1.3.6.1.4.1.6247.29.1.6 | csat5060UnitStatus | CSAT-5060 |
| 1.3.6.1.4.1.6247.29.1.6.2 | csat5060MaintenanceParameters | CSAT-5060 |