All MIBs › CPQSTDEQ-MIB › cpqSePCCardSlotThermalSensor
cpqSePCCardSlotThermalSensor
Module: CPQSTDEQ-MIB
OID (symbolic): CPQSTDEQ-MIB::cpqSePCCardSlotThermalSensor
OID (numeric): 1.3.6.1.4.1.232.1.2.14.1.1.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Defines the Thermal Sensor ID that monitors this PC Card Slot. A value of zero indicates that a sensor is not present or unknown for this slot. A non-zero value indicates the sensor ID as defined by the platform firmware.
What is cpqSePCCardSlotThermalSensor?
This OID identifies the platform-firmware-defined thermal sensor ID assigned to monitor this PC Card slot, where a value of zero means no sensor is present or the sensor is unknown. An admin correlating a PC Card thermal fault with the system's broader sensor readings uses this sensor ID to find the matching temperature sensor in the platform's sensor table. For example, a nonzero sensor ID reported here would let an admin cross-reference the exact temperature sensor responsible for triggering a thermalDegraded condition on that slot.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.1.2.14.1.1.7 snmpwalk -v2c -c public <target> CPQSTDEQ-MIB::cpqSePCCardSlotThermalSensor
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.232.1.2.14.1.1.7.1 snmpget -v2c -c public <target> CPQSTDEQ-MIB::cpqSePCCardSlotThermalSensor.1
Start monitoring HP ProLiant server (CPU/memory/system board) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQSTDEQ-MIB::cpqSePCCardSlotThermalSensor OID value, configure state conditions and alerts, and monitor any HP ProLiant server (CPU/memory/system board) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.1 | cpqStdEquipment | CPQSTDEQ-MIB |
| 1.3.6.1.4.1.232.1.2 | cpqSeComponent | CPQSTDEQ-MIB |
| 1.3.6.1.4.1.232.1.2.14 | cpqSePCCard | CPQSTDEQ-MIB |
| 1.3.6.1.4.1.232.1.2.14.1 | cpqSePCCardSlotTable | CPQSTDEQ-MIB |
| 1.3.6.1.4.1.232.1.2.14.1.1 | cpqSePCCardSlotEntry | CPQSTDEQ-MIB |
| 1.3.6.1.4.1.232.1.2.14.1.1.7 | cpqSePCCardSlotThermalSensor | CPQSTDEQ-MIB |