All MIBs › CPQSTDEQ-MIB › cpqSeFixedDiskIndex
cpqSeFixedDiskIndex
Module: CPQSTDEQ-MIB
OID (symbolic): CPQSTDEQ-MIB::cpqSeFixedDiskIndex
OID (numeric): 1.3.6.1.4.1.232.1.2.12.1.1.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: An index that uniquely specifies this entry. Each possible
index value indicates a specific drive as shown in the table
below:
fixedDiskIndex IDE/ESDI Controller Drive Unit
============= =================== ==========
0 Primary 1
1 Primary 2
2 Secondary 1
3 Secondary 2
Any other index value would be implementation specific.What is cpqSeFixedDiskIndex?
This OID is the unique index identifying a fixed disk entry, where each index value corresponds to a specific IDE/ESDI controller channel and drive unit, such as index 0 for the primary controller's first drive and index 2 for the secondary controller's first drive. An admin uses this mapping to know exactly which physical drive bay and controller channel a given row's cylinder, head, and capacity fields describe. For example, index 2 would describe the drive attached as unit 1 on the secondary IDE/ESDI controller, distinct from index 0 which describes unit 1 on the primary controller.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.1.2.12.1.1.1 snmpwalk -v2c -c public <target> CPQSTDEQ-MIB::cpqSeFixedDiskIndex
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.232.1.2.12.1.1.1.1 snmpget -v2c -c public <target> CPQSTDEQ-MIB::cpqSeFixedDiskIndex.1
Start monitoring HP ProLiant server (CPU/memory/system board) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQSTDEQ-MIB::cpqSeFixedDiskIndex OID value, configure state conditions and alerts, and monitor any HP ProLiant server (CPU/memory/system board) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.1 | cpqStdEquipment | CPQSTDEQ-MIB |
| 1.3.6.1.4.1.232.1.2 | cpqSeComponent | CPQSTDEQ-MIB |
| 1.3.6.1.4.1.232.1.2.12 | cpqSeFixedDisk | CPQSTDEQ-MIB |
| 1.3.6.1.4.1.232.1.2.12.1 | cpqSeFixedDiskTable | CPQSTDEQ-MIB |
| 1.3.6.1.4.1.232.1.2.12.1.1 | cpqSeFixedDiskEntry | CPQSTDEQ-MIB |
| 1.3.6.1.4.1.232.1.2.12.1.1.1 | cpqSeFixedDiskIndex | CPQSTDEQ-MIB |