Type: INTEGER

Access: read-only

Description: This value specifies the status of the hot plug slot.

The hot plug slot status is set as follows:

noError(1) The slot is operating normally.

generalError(2) A general error occurred.

wrongRevision(3) The revision of the replacement adapter was different from the original adapter.

wrongBoard(4) The model of the replacement adapter was different from the original adapter.

cannotConfig(5) The adapter could not be configured.

powerFault(6) A power fault occurred for the slot.

unexpectedPowerLoss(7) Power was unexpectedly lost from the slot.

wrongSpeed(8) The adapter cannot be run at the current bus speed.

functionlFailure(9) The adapter is not functioning correctly. This may be caused by a cabling problem.

What is cpqSiHotPlugSlotErrorStatus?

This read-only integer gives a detailed error code for a hot-plug slot, distinguishing conditions like no error, a general error, wrong revision, wrong board, cannot configure, or power fault. It matters for diagnosing exactly why a hot-plug replacement didn't come online correctly. For example, after swapping in a replacement card, an admin sees cpqSiHotPlugSlotErrorStatus report wrongBoard(4), realizing the wrong model of adapter was installed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.2.2.9.4.1.6
snmpwalk -v2c -c public <target> CPQSINFO-MIB::cpqSiHotPlugSlotErrorStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.2.2.9.4.1.6.1
snmpget -v2c -c public <target> CPQSINFO-MIB::cpqSiHotPlugSlotErrorStatus.1

Start monitoring HP/Compaq ProLiant server (system info) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQSINFO-MIB::cpqSiHotPlugSlotErrorStatus OID value, configure state conditions and alerts, and monitor any HP/Compaq ProLiant server (system info) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.2cpqSystemInfoCPQSINFO-MIB
1.3.6.1.4.1.232.2.2cpqSiComponentCPQSINFO-MIB
1.3.6.1.4.1.232.2.2.9cpqSiHotPlugSlotCPQSINFO-MIB
1.3.6.1.4.1.232.2.2.9.4cpqSiHotPlugSlotTableCPQSINFO-MIB
1.3.6.1.4.1.232.2.2.9.4.1cpqSiHotPlugSlotEntryCPQSINFO-MIB
1.3.6.1.4.1.232.2.2.9.4.1.6cpqSiHotPlugSlotErrorStatusCPQSINFO-MIB