CPI-UNITY-MIB :: trapBranchCritHighVoltage

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › CPI-UNITY-MIB › trapBranchCritHighVoltage

trapBranchCritHighVoltage

Module: CPI-UNITY-MIB

OID (symbolic): CPI-UNITY-MIB::trapBranchCritHighVoltage

OID (numeric): 1.3.6.1.4.1.30932.1.10.1.1.8.3.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Enable/Disable notification of Critical High Voltage on the Branch in a trap.

What is trapBranchCritHighVoltage?

This read-write enabled/disabled flag controls whether the PDU sends an SNMP trap to the configured trap receiver for a branch circuit's voltage climbing to a critical high level. Enabling it lets a centralized SNMP monitoring system, such as IPNetwork Monitor, raise the alert automatically the instant it happens rather than waiting for the next scheduled poll. For example, when a branch circuit's voltage climbing to a critical high level actually happens on this unit, an NMS like IPNetwork Monitor receiving the trap and immediately raising an alert on its dashboard is exactly the effect this setting produces.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.30932.1.10.1.1.8.3.4
snmpwalk -v2c -c public <target> CPI-UNITY-MIB::trapBranchCritHighVoltage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.30932.1.10.1.1.8.3.4.1
snmpget -v2c -c public <target> CPI-UNITY-MIB::trapBranchCritHighVoltage.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.30932.1.10.1.1.8.3.4.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> trapBranchCritHighVoltage.1

Start monitoring Chatsworth Products (CPI) eConnect rack PDU/cabinet management unit with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPI-UNITY-MIB::trapBranchCritHighVoltage OID value, configure state conditions and alerts, and monitor any Chatsworth Products (CPI) eConnect rack PDU/cabinet management unit from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.30932cpiCPI-UNITY-MIB
1.3.6.1.4.1.30932.1productsCPI-UNITY-MIB
1.3.6.1.4.1.30932.1.10unityCPI-UNITY-MIB
1.3.6.1.4.1.30932.1.10.1econnectCPI-UNITY-MIB
1.3.6.1.4.1.30932.1.10.1.1econnectConfigurationCPI-UNITY-MIB
1.3.6.1.4.1.30932.1.10.1.1.8routingCPI-UNITY-MIB
1.3.6.1.4.1.30932.1.10.1.1.8.3trapRoutingCPI-UNITY-MIB
1.3.6.1.4.1.30932.1.10.1.1.8.3.4trapBranchCritHighVoltageCPI-UNITY-MIB