CPE-DSL-MIB :: cpeSysInfoUptime

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPE-DSL-MIBcpeSysInfoUptime

cpeSysInfoUptime

Module: CPE-DSL-MIB

OID (symbolic): CPE-DSL-MIB::cpeSysInfoUptime

OID (numeric): 1.3.6.1.4.1.16972.1.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: It is the working time since CPE rebooted.

What is cpeSysInfoUptime?

The number of seconds the CPE, a customer-premises DSL modem or router, has been running since its last reboot. A low uptime value on an unexpected check tells the admin the device recently rebooted, which could explain a service interruption reported by the customer. A support technician sees cpeSysInfoUptime reset to a small number and confirms the customer's DSL modem power-cycled, matching the timing of their reported outage.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.16972.1.1
snmpwalk -v2c -c public <target> CPE-DSL-MIB::cpeSysInfoUptime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.16972.1.1.1
snmpget -v2c -c public <target> CPE-DSL-MIB::cpeSysInfoUptime.1

Start monitoring Huawei xDSL CPE modem/router with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPE-DSL-MIB::cpeSysInfoUptime OID value, configure state conditions and alerts, and monitor any Huawei xDSL CPE modem/router from a single console.

How to Use in IPNetwork Monitor

Select a Huawei xDSL CPE modem/router as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cpeSysInfoUptime into the Find box to locate it in the OID tree, then select it and click OK. It is the working time since CPE rebooted. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the value is unexpectedly low (e.g. under 10 minutes), since that indicates a recent, possibly unplanned, reboot or restart. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.16972cpeDSLCPE-DSL-MIB
1.3.6.1.4.1.16972.1cpeSysInfoCPE-DSL-MIB
1.3.6.1.4.1.16972.1.1cpeSysInfoUptimeCPE-DSL-MIB