All MIBs › COPPER-MOUNTAIN-NETWORKS-DSL-MIB › cmMaintCmdSecondaryIpAddr
cmMaintCmdSecondaryIpAddr
Module: COPPER-MOUNTAIN-NETWORKS-DSL-MIB
OID (symbolic): COPPER-MOUNTAIN-NETWORKS-DSL-MIB::cmMaintCmdSecondaryIpAddr
OID (numeric): 1.3.6.1.4.1.1996.20.16.1.1.7
Node type: OBJECT-TYPE
Type: IpAddress
Access: read-write
Description: This is the IpAddress of the secondary file server to use in executing the command. If an address of all 0's is entered, no save will be attempted to the secondary and no event will be generated. If a transfer to the primary fails and there is no secondary address configured, the CommandStatus will be 'failed'.
For 'bulkCPEDownload', the value of this object is ignored.
For 'configRestore', the value of this object is ignored.
Default: 0.0.0.0
What is cmMaintCmdSecondaryIpAddr?
cmMaintCmdSecondaryIpAddr is a read-write IP address for a fallback file server that a maintenance command will use if the primary transfer fails, with the description noting the command's status becomes failed if no secondary is configured and the primary fails, and that this field is ignored entirely for bulkCPEDownload and configRestore. An administrator configures a secondary server as a redundancy measure for commands like configBackup, so a single file-server outage doesn't cause a missed backup. For example, if the primary backup server is temporarily unreachable, having cmMaintCmdSecondaryIpAddr set would let the configBackup still succeed against the fallback server instead of reporting failed.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1996.20.16.1.1.7 snmpwalk -v2c -c public <target> COPPER-MOUNTAIN-NETWORKS-DSL-MIB::cmMaintCmdSecondaryIpAddr
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1996.20.16.1.1.7.1 snmpget -v2c -c public <target> COPPER-MOUNTAIN-NETWORKS-DSL-MIB::cmMaintCmdSecondaryIpAddr.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.1996.20.16.1.1.7.1 a <value>
Start monitoring Copper Mountain Networks DSL access equipment (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the COPPER-MOUNTAIN-NETWORKS-DSL-MIB::cmMaintCmdSecondaryIpAddr OID value, configure state conditions and alerts, and monitor any Copper Mountain Networks DSL access equipment (legacy) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1996 | coppermountain | COPPER-MOUNTAIN-NETWORKS-DSL-MIB |
| 1.3.6.1.4.1.1996.20 | cmCE200 | COPPER-MOUNTAIN-NETWORKS-DSL-MIB |
| 1.3.6.1.4.1.1996.20.16 | cmMaint | COPPER-MOUNTAIN-NETWORKS-DSL-MIB |
| 1.3.6.1.4.1.1996.20.16.1 | cmMaintCmdTable | COPPER-MOUNTAIN-NETWORKS-DSL-MIB |
| 1.3.6.1.4.1.1996.20.16.1.1 | cmMaintCmdEntry | COPPER-MOUNTAIN-NETWORKS-DSL-MIB |
| 1.3.6.1.4.1.1996.20.16.1.1.7 | cmMaintCmdSecondaryIpAddr | COPPER-MOUNTAIN-NETWORKS-DSL-MIB |