COMTROL-ES8510-MIB :: rateLimitingIngressLimitType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCOMTROL-ES8510-MIBrateLimitingIngressLimitType

rateLimitingIngressLimitType

Module: COMTROL-ES8510-MIB

OID (symbolic): COMTROL-ES8510-MIB::rateLimitingIngressLimitType

OID (numeric): 1.3.6.1.4.1.2882.2.1.1.3.3.1.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The type of ingress packets to be filtered.

What is rateLimitingIngressLimitType?

This read-write setting selects which category of inbound traffic the port's rate limiter actually inspects: all traffic, broadcast plus multicast plus flooded unicast, broadcast plus multicast only, or broadcast alone. An admin uses it to narrow storm-control enforcement to just the traffic types that tend to cause storms, without throttling legitimate unicast flows. For example, setting it to broadcastOnly(4) on a port feeding a large flat VLAN stops broadcast storms from a misbehaving NIC while leaving normal multicast video streams untouched.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2882.2.1.1.3.3.1.1.2
snmpwalk -v2c -c public <target> COMTROL-ES8510-MIB::rateLimitingIngressLimitType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2882.2.1.1.3.3.1.1.2.1
snmpget -v2c -c public <target> COMTROL-ES8510-MIB::rateLimitingIngressLimitType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2882.2.1.1.3.3.1.1.2.1 i <value>

Start monitoring Comtrol ES8510 industrial managed Ethernet switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the COMTROL-ES8510-MIB::rateLimitingIngressLimitType OID value, configure state conditions and alerts, and monitor any Comtrol ES8510 industrial managed Ethernet switch from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2882comtrolCOMTROL-ES8510-MIB
1.3.6.1.4.1.2882.2productsCOMTROL-ES8510-MIB
1.3.6.1.4.1.2882.2.1managedSwitchCOMTROL-ES8510-MIB
1.3.6.1.4.1.2882.2.1.1es8510COMTROL-ES8510-MIB
1.3.6.1.4.1.2882.2.1.1.3portConfigurationCOMTROL-ES8510-MIB
1.3.6.1.4.1.2882.2.1.1.3.3rateLimitingCOMTROL-ES8510-MIB
1.3.6.1.4.1.2882.2.1.1.3.3.1rateLimitingTableCOMTROL-ES8510-MIB
1.3.6.1.4.1.2882.2.1.1.3.3.1.1rateLimitingEntryCOMTROL-ES8510-MIB
1.3.6.1.4.1.2882.2.1.1.3.3.1.1.2rateLimitingIngressLimitTypeCOMTROL-ES8510-MIB