COMTROL-ES8510-MIB :: dryOutputOffPeriodConfig

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCOMTROL-ES8510-MIBdryOutputOffPeriodConfig

dryOutputOffPeriodConfig

Module: COMTROL-ES8510-MIB

OID (symbolic): COMTROL-ES8510-MIB::dryOutputOffPeriodConfig

OID (numeric): 1.3.6.1.4.1.2882.2.1.1.10.1.1.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The fault relay will be opened after a period (in seconds). Together with dryOutputOnPeriodConfig, the fault relay can be configured to continue on and off.

What is dryOutputOffPeriodConfig?

This read-write value, from 1 to 1000 seconds, sets how long the fault relay's dry output stays open between activations when cycling in a timed on/off mode, working together with dryOutputOnPeriodConfig. An admin tunes both periods together to shape the resulting alarm pattern's rhythm. For example, pairing a 5-second on period with a 10-second off period produces a slow, intermittent blink pattern on a connected alarm light rather than a steady continuous signal.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2882.2.1.1.10.1.1.1.5
snmpwalk -v2c -c public <target> COMTROL-ES8510-MIB::dryOutputOffPeriodConfig

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2882.2.1.1.10.1.1.1.5.1
snmpget -v2c -c public <target> COMTROL-ES8510-MIB::dryOutputOffPeriodConfig.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2882.2.1.1.10.1.1.1.5.1 i <value>

Start monitoring Comtrol ES8510 industrial managed Ethernet switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the COMTROL-ES8510-MIB::dryOutputOffPeriodConfig OID value, configure state conditions and alerts, and monitor any Comtrol ES8510 industrial managed Ethernet switch from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2882comtrolCOMTROL-ES8510-MIB
1.3.6.1.4.1.2882.2productsCOMTROL-ES8510-MIB
1.3.6.1.4.1.2882.2.1managedSwitchCOMTROL-ES8510-MIB
1.3.6.1.4.1.2882.2.1.1es8510COMTROL-ES8510-MIB
1.3.6.1.4.1.2882.2.1.1.10warningCOMTROL-ES8510-MIB
1.3.6.1.4.1.2882.2.1.1.10.1faultRelayCOMTROL-ES8510-MIB
1.3.6.1.4.1.2882.2.1.1.10.1.1faultRelayTableCOMTROL-ES8510-MIB
1.3.6.1.4.1.2882.2.1.1.10.1.1.1faultRelayEntryCOMTROL-ES8510-MIB
1.3.6.1.4.1.2882.2.1.1.10.1.1.1.5dryOutputOffPeriodConfigCOMTROL-ES8510-MIB