CODAN-MIB :: wvRelayId

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCODAN-MIBwvRelayId

wvRelayId

Module: CODAN-MIB

OID (symbolic): CODAN-MIB::wvRelayId

OID (numeric): 1.3.6.1.4.1.23304.1.1.1.4.1.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The entry index.

What is wvRelayId?

This read-only integer, from 1 to 7, indexes one entry in the terminal's relay table, which covers the unit's physical alarm relay outputs. A manager uses this index to identify which specific relay the accompanying operation, state, and status columns describe. For example, relay index 1 might be wired to an external siren while index 2 drives a status light in the equipment room.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.23304.1.1.1.4.1.1.1
snmpwalk -v2c -c public <target> CODAN-MIB::wvRelayId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.23304.1.1.1.4.1.1.1.1
snmpget -v2c -c public <target> CODAN-MIB::wvRelayId.1

Start monitoring Codan 8800 DMR microwave radio link equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CODAN-MIB::wvRelayId OID value, configure state conditions and alerts, and monitor any Codan 8800 DMR microwave radio link equipment from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.23304codanGroupCODAN-SMI
1.3.6.1.4.1.23304.1codanMibsCODAN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.23304.1.1minetMIBCODAN-MIB
1.3.6.1.4.1.23304.1.1.1wvConfigurationCODAN-MIB
1.3.6.1.4.1.23304.1.1.1.4wvRelaysCODAN-MIB
1.3.6.1.4.1.23304.1.1.1.4.1wvRelayTableCODAN-MIB
1.3.6.1.4.1.23304.1.1.1.4.1.1wvRelayEntryCODAN-MIB
1.3.6.1.4.1.23304.1.1.1.4.1.1.1wvRelayIdCODAN-MIB