CODAN-MIB :: wvLinkCurrentBER

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCODAN-MIBwvLinkCurrentBER

wvLinkCurrentBER

Module: CODAN-MIB

OID (symbolic): CODAN-MIB::wvLinkCurrentBER

OID (numeric): 1.3.6.1.4.1.23304.1.1.3.17

Node type: OBJECT-TYPE

Type: FloatingPoint

Access: read-only

Description: The Bit Error Rate encountered by the interface Link in the current 15 minute interval.

What is wvLinkCurrentBER?

This read-only floating-point object reports the Bit Error Rate measured on the link interface during the current, in-progress 15-minute interval. An engineer watches this figure as the most immediate BER reading available, more responsive than the cumulative wvlinkBER since it resets every 15 minutes. For example, a spike in wvLinkCurrentBER without a corresponding spike in the cumulative wvlinkBER would confirm the elevated error rate just started within this interval.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.23304.1.1.3.17
snmpwalk -v2c -c public <target> CODAN-MIB::wvLinkCurrentBER

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.23304.1.1.3.17.1
snmpget -v2c -c public <target> CODAN-MIB::wvLinkCurrentBER.1

Start monitoring Codan 8800 DMR microwave radio link equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CODAN-MIB::wvLinkCurrentBER OID value, configure state conditions and alerts, and monitor any Codan 8800 DMR microwave radio link equipment from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.23304codanGroupCODAN-SMI
1.3.6.1.4.1.23304.1codanMibsCODAN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.23304.1.1minetMIBCODAN-MIB
1.3.6.1.4.1.23304.1.1.3wvPerformanceCODAN-MIB
1.3.6.1.4.1.23304.1.1.3.17wvLinkCurrentBERCODAN-MIB