CODAN-MIB :: wvLinkCurrentBBER

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCODAN-MIBwvLinkCurrentBBER

wvLinkCurrentBBER

Module: CODAN-MIB

OID (symbolic): CODAN-MIB::wvLinkCurrentBBER

OID (numeric): 1.3.6.1.4.1.23304.1.1.3.19

Node type: OBJECT-TYPE

Type: FloatingPoint

Access: read-only

Description: The Background Blocks Error Rate encountered by the interface Link in the current 15 minute interval.

What is wvLinkCurrentBBER?

This read-only floating-point object reports the Background Blocks Error Rate measured on the link interface during the current, in-progress 15-minute interval. An engineer checks this for the most up-to-date view of subtle block-level errors happening right now, ahead of when this interval's data rolls into the historical table. For example, an operator noticing wvLinkCurrentBBER climbing steadily through several consecutive checks within the same interval could flag a developing issue before the interval even finishes.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.23304.1.1.3.19
snmpwalk -v2c -c public <target> CODAN-MIB::wvLinkCurrentBBER

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.23304.1.1.3.19.1
snmpget -v2c -c public <target> CODAN-MIB::wvLinkCurrentBBER.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> wvLinkCurrentBBER.1

Start monitoring Codan 8800 DMR microwave radio link equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CODAN-MIB::wvLinkCurrentBBER OID value, configure state conditions and alerts, and monitor any Codan 8800 DMR microwave radio link equipment from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.23304codanGroupCODAN-SMI
1.3.6.1.4.1.23304.1codanMibsCODAN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.23304.1.1minetMIBCODAN-MIB
1.3.6.1.4.1.23304.1.1.3wvPerformanceCODAN-MIB
1.3.6.1.4.1.23304.1.1.3.19wvLinkCurrentBBERCODAN-MIB