CISCOSB-TIMESYNCHRONIZATION-MIB :: rlSntpNtpConfigSyncSrvIfIndex

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCOSB-TIMESYNCHRONIZATION-MIBrlSntpNtpConfigSyncSrvIfIndex

rlSntpNtpConfigSyncSrvIfIndex

Module: CISCOSB-TIMESYNCHRONIZATION-MIB

OID (symbolic): CISCOSB-TIMESYNCHRONIZATION-MIB::rlSntpNtpConfigSyncSrvIfIndex

OID (numeric): 1.3.6.1.4.1.9.6.1.101.92.2.1.11

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The interface addressed of the synced server.

What is rlSntpNtpConfigSyncSrvIfIndex?

This read-only INTEGER reports the ifIndex of the interface used to reach the server the device is actively synced to. An admin troubleshooting a time-sync failure over on the expected interface can check this to see if the device silently failed over to a server reachable on a different interface. For example, if the primary interface link drops, this value might change from the management interface's ifIndex to a data VLAN interface's ifIndex when a backup server is used instead.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.6.1.101.92.2.1.11
snmpwalk -v2c -c public <target> CISCOSB-TIMESYNCHRONIZATION-MIB::rlSntpNtpConfigSyncSrvIfIndex

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.6.1.101.92.2.1.11.1
snmpget -v2c -c public <target> CISCOSB-TIMESYNCHRONIZATION-MIB::rlSntpNtpConfigSyncSrvIfIndex.1

Start monitoring Cisco Small Business switches and routers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCOSB-TIMESYNCHRONIZATION-MIB::rlSntpNtpConfigSyncSrvIfIndex OID value, configure state conditions and alerts, and monitor any Cisco Small Business switches and routers from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.6otherEnterprisesCISCO-SMI
1.3.6.1.4.1.9.6.1ciscoSBCISCO-SMI
1.3.6.1.4.1.9.6.1.101switch001CISCOSB-MIB
1.3.6.1.4.1.9.6.1.101.92rlTimeSynchronizationCISCOSB-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.6.1.101.92.2rlSntpNtpClientCISCOSB-TIMESYNCHRONIZATION-MIB
1.3.6.1.4.1.9.6.1.101.92.2.1rlSntpNtpConfigCISCOSB-TIMESYNCHRONIZATION-MIB
1.3.6.1.4.1.9.6.1.101.92.2.1.11rlSntpNtpConfigSyncSrvIfIndexCISCOSB-TIMESYNCHRONIZATION-MIB