CISCO-VOICE-TONE-CADENCE-MIB :: cvtcTonePlanVifCount

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-VOICE-TONE-CADENCE-MIB › cvtcTonePlanVifCount

cvtcTonePlanVifCount

Module: CISCO-VOICE-TONE-CADENCE-MIB

OID (symbolic): CISCO-VOICE-TONE-CADENCE-MIB::cvtcTonePlanVifCount

OID (numeric): 1.3.6.1.4.1.9.9.356.1.1.1.1.2

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: This object indicates the number of voice interfaces are using the tone plan.

What is cvtcTonePlanVifCount?

This read-only Gauge32 reports how many voice interfaces are currently using a particular tone plan. Administrators use it to understand the operational impact of a tone plan before modifying or deleting it, since a plan in active use by many interfaces requires more caution to change than one with zero usage. For example, before deleting a custom tone plan, an admin would check this count is zero to avoid disrupting interfaces actively relying on it.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.356.1.1.1.1.2
snmpwalk -v2c -c public <target> CISCO-VOICE-TONE-CADENCE-MIB::cvtcTonePlanVifCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.356.1.1.1.1.2.1
snmpget -v2c -c public <target> CISCO-VOICE-TONE-CADENCE-MIB::cvtcTonePlanVifCount.1

Start monitoring Cisco voice gateway/router with voice interface (tone plans) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-VOICE-TONE-CADENCE-MIB::cvtcTonePlanVifCount OID value, configure state conditions and alerts, and monitor any Cisco voice gateway/router with voice interface (tone plans) from a single console.

How to Use in IPNetwork Monitor

Select a Cisco voice gateway/router with voice interface (tone plans) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cvtcTonePlanVifCount into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This object indicates the number of voice interfaces are using the tone plan. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.356ciscoVoiceToneCadenceMIBCISCO-VOICE-TONE-CADENCE-MIB
1.3.6.1.4.1.9.9.356.1ciscoVoiceToneCadenceMIBObjectsCISCO-VOICE-TONE-CADENCE-MIB
1.3.6.1.4.1.9.9.356.1.1cVoiceToneCadenceConfigCISCO-VOICE-TONE-CADENCE-MIB
1.3.6.1.4.1.9.9.356.1.1.1cvtcTonePlanTableCISCO-VOICE-TONE-CADENCE-MIB
1.3.6.1.4.1.9.9.356.1.1.1.1cvtcTonePlanEntryCISCO-VOICE-TONE-CADENCE-MIB
1.3.6.1.4.1.9.9.356.1.1.1.1.2cvtcTonePlanVifCountCISCO-VOICE-TONE-CADENCE-MIB