CISCO-VIRTUAL-SWITCH-MIB :: cvsSwitchMode

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-VIRTUAL-SWITCH-MIBcvsSwitchMode

cvsSwitchMode

Module: CISCO-VIRTUAL-SWITCH-MIB

OID (symbolic): CISCO-VIRTUAL-SWITCH-MIB::cvsSwitchMode

OID (numeric): 1.3.6.1.4.1.9.9.388.1.1.4

Node type: OBJECT-TYPE

Type: VSSwitchMode

Access: read-write

Description: Converting a standalone switch in the regular switch architecture to a switch in the virtual switch architecture. Or converting a switch in the virtual switch architecture to a standalone switch in the regular switch architecture. And the value of this object can only be set to one of mode where the corresponding bits in cvsSwitchCapability is set.

To prevent vague switch status, this action will not only change the switch mode, but also reload the device automatically to activate to the new switch mode.

What is cvsSwitchMode?

This read-write value both reports and controls whether a chassis operates as a standalone switch or as part of the virtual switch architecture, and can only be set to a mode the chassis's capability bits actually support. An admin cares because changing this value is the actual mechanism for converting a chassis between standalone and virtual switch operation, and the MIB warns the action does more than just flip the mode, to avoid leaving the switch in an ambiguous state. For example, setting this to a virtual-switch value on a chassis whose capability field doesn't include that bit would be rejected rather than silently accepted.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.388.1.1.4
snmpwalk -v2c -c public <target> CISCO-VIRTUAL-SWITCH-MIB::cvsSwitchMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.388.1.1.4.1
snmpget -v2c -c public <target> CISCO-VIRTUAL-SWITCH-MIB::cvsSwitchMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9.9.388.1.1.4.1 s <value>

Start monitoring Cisco Catalyst 6500/6800-series switches (VSS) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-VIRTUAL-SWITCH-MIB::cvsSwitchMode OID value, configure state conditions and alerts, and monitor any Cisco Catalyst 6500/6800-series switches (VSS) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.388ciscoVirtualSwitchMIBCISCO-VIRTUAL-SWITCH-MIB
1.3.6.1.4.1.9.9.388.1ciscoVirtualSwitchMIBObjectsCISCO-VIRTUAL-SWITCH-MIB
1.3.6.1.4.1.9.9.388.1.1cvsGlobalObjectsCISCO-VIRTUAL-SWITCH-MIB
1.3.6.1.4.1.9.9.388.1.1.4cvsSwitchModeCISCO-VIRTUAL-SWITCH-MIB