CISCO-UDLDP-MIB :: cudldpInterfaceAggressiveMode

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-UDLDP-MIB › cudldpInterfaceAggressiveMode

cudldpInterfaceAggressiveMode

Module: CISCO-UDLDP-MIB

OID (symbolic): CISCO-UDLDP-MIB::cudldpInterfaceAggressiveMode

OID (numeric): 1.3.6.1.4.1.9.9.118.1.2.1.1.3

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: An indication of whether the UDLDP aggressive mode is enabled on this interface. If the aggressive mode is set to 'true', an active port may be shutdown in case of the abrupt loss of its neighbor(s) because the loss of communication (heartbeat) with the neighbor(s) is assumed to be caused by a fault; thus, the cudldpInterfaceOperStatus of the active port will be 'shutdown'. Instead, when the aggressive mode is set to 'false', and if there is a loss of communication with the neighbor(s), then the cudldpInterfaceOperStatus of the active port will be 'indeterminant'. Therefore, this mode is recommended only for links that don't use hubs, media converters or similar devices, and where the unexpected loss of the port's neighbor is not an admissible condition. cudldpInterfaceAggressiveMode is deprecated and replaced with cudldpInterfaceAdminMode.

What is cudldpInterfaceAggressiveMode?

A read-write flag indicating whether UDLD aggressive mode is enabled on the interface, which causes an active port to be shut down if heartbeat communication with its neighbor is abruptly lost.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.118.1.2.1.1.3
snmpwalk -v2c -c public <target> CISCO-UDLDP-MIB::cudldpInterfaceAggressiveMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.118.1.2.1.1.3.1
snmpget -v2c -c public <target> CISCO-UDLDP-MIB::cudldpInterfaceAggressiveMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9.9.118.1.2.1.1.3.1 s <value>

Start monitoring Cisco switches (fiber-optic uplinks/aggregation, UDLD) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UDLDP-MIB::cudldpInterfaceAggressiveMode OID value, configure state conditions and alerts, and monitor any Cisco switches (fiber-optic uplinks/aggregation, UDLD) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.118ciscoUdldpMIBCISCO-UDLDP-MIB
1.3.6.1.4.1.9.9.118.1ciscoUdldpMIBObjectsCISCO-UDLDP-MIB
1.3.6.1.4.1.9.9.118.1.2cudldpInterfaceCISCO-UDLDP-MIB
1.3.6.1.4.1.9.9.118.1.2.1cudldpInterfaceTableCISCO-UDLDP-MIB
1.3.6.1.4.1.9.9.118.1.2.1.1cudldpInterfaceEntryCISCO-UDLDP-MIB
1.3.6.1.4.1.9.9.118.1.2.1.1.3cudldpInterfaceAggressiveModeCISCO-UDLDP-MIB