CISCO-SYSLOG-MIB :: clogHistTableMaxLength

MIB Reference — IPNetwork Monitor

All MIBsCISCO-SYSLOG-MIBclogHistTableMaxLength

clogHistTableMaxLength

Module: CISCO-SYSLOG-MIB

OID (symbolic): CISCO-SYSLOG-MIB::clogHistTableMaxLength

OID (numeric): 1.3.6.1.4.1.9.9.41.1.2.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description:

The upper limit on the number of entries that the clogHistoryTable may contain. A value of 0 will prevent any history from being retained. When this table is full, the oldest entry will be deleted and a new one will be created.

What is clogHistTableMaxLength?

A read-write value setting the maximum number of entries retained in the syslog history table; setting it to 0 disables history retention, and the oldest entries are dropped once the table is full.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.41.1.2.1
snmpwalk -v2c -c public <target> CISCO-SYSLOG-MIB::clogHistTableMaxLength

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.41.1.2.1.1
snmpget -v2c -c public <target> CISCO-SYSLOG-MIB::clogHistTableMaxLength.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9.9.41.1.2.1.1 i <value>

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.9ciscoCISCO-SMI
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.41ciscoSyslogMIBCISCO-SYSLOG-MIB
1.3.6.1.4.1.9.9.41.1ciscoSyslogMIBObjectsCISCO-SYSLOG-MIB
1.3.6.1.4.1.9.9.41.1.2clogHistoryCISCO-SYSLOG-MIB
1.3.6.1.4.1.9.9.41.1.2.1clogHistTableMaxLengthCISCO-SYSLOG-MIB