CISCO-SONET-MIB :: cssLOSs

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-SONET-MIBcssLOSs

cssLOSs

Module: CISCO-SONET-MIB

OID (symbolic): CISCO-SONET-MIB::cssLOSs

OID (numeric): 1.3.6.1.4.1.9.9.126.1.6.1.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of Loss of signals(LOS) encountered by a SONET/SDH Section. A high value for this object may indicate a problem with the Sonet Section layer.

What is cssLOSs?

Counts Loss of Signal (LOS) events on a SONET/SDH Section; a high count suggests a problem at the physical/Section layer such as a cable or optics failure.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.126.1.6.1.1.1
snmpwalk -v2c -c public <target> CISCO-SONET-MIB::cssLOSs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.126.1.6.1.1.1.1
snmpget -v2c -c public <target> CISCO-SONET-MIB::cssLOSs.1

Start monitoring Cisco SONET/SDH transport routers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-SONET-MIB::cssLOSs OID value, configure state conditions and alerts, and monitor any Cisco SONET/SDH transport routers from a single console.

How to Use in IPNetwork Monitor

Select a Cisco SONET/SDH transport router as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cssLOSs into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of Loss of signals(LOS) encountered by a SONET/SDH Section. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline (in loss of signals), since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.126ciscoSonetMIBCISCO-SONET-MIB
1.3.6.1.4.1.9.9.126.1ciscoSonetMIBObjectsCISCO-SONET-MIB
1.3.6.1.4.1.9.9.126.1.6csStatsCISCO-SONET-MIB
1.3.6.1.4.1.9.9.126.1.6.1csStatsTableCISCO-SONET-MIB
1.3.6.1.4.1.9.9.126.1.6.1.1csStatsEntryCISCO-SONET-MIB
1.3.6.1.4.1.9.9.126.1.6.1.1.1cssLOSsCISCO-SONET-MIB