CISCO-SNA-LLC-MIB :: llcCcAdminNw

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-SNA-LLC-MIBllcCcAdminNw

llcCcAdminNw

Module: CISCO-SNA-LLC-MIB

OID (symbolic): CISCO-SNA-LLC-MIB::llcCcAdminNw

OID (numeric): 1.3.6.1.4.1.9.10.8.1.3.1.1.15

Node type: OBJECT-TYPE

Type: Integer32

Access: read-create

Description: This object denotes the value for the number of IPDUs that must be acknowledged before the working window size (Ww) can be incremented by 1 when the working window is not equal to the maximum transmit window size (TW). It controls the gradual incrementing of Ww in congestion situations.

This function is not described in the IEEE 802.2 specification [5]. However, it is listed in the IBM Token-Ring Network Architecture Reference [6] as the Nw parameter and is widely implemented.

What is llcCcAdminNw?

This read-create object configures the number of I-PDUs that must be acknowledged before the current working transmit window can be incremented by one, controlling how gradually the window grows toward its configured maximum.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.10ciscoExperimentCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.10.8ciscoSnaLlcMIBCISCO-SNA-LLC-MIB
1.3.6.1.4.1.9.10.8.1ciscoSnaLlcMIBObjectsCISCO-SNA-LLC-MIB
1.3.6.1.4.1.9.10.8.1.3llcCcGroupCISCO-SNA-LLC-MIB
1.3.6.1.4.1.9.10.8.1.3.1llcCcAdminTableCISCO-SNA-LLC-MIB
1.3.6.1.4.1.9.10.8.1.3.1.1llcCcAdminEntryCISCO-SNA-LLC-MIB
1.3.6.1.4.1.9.10.8.1.3.1.1.15llcCcAdminNwCISCO-SNA-LLC-MIB