CISCO-RF-SUPPLEMENTAL-MIB :: cRfSupSysRunningConfigSyncTime

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-RF-SUPPLEMENTAL-MIB › cRfSupSysRunningConfigSyncTime

cRfSupSysRunningConfigSyncTime

Module: CISCO-RF-SUPPLEMENTAL-MIB

OID (symbolic): CISCO-RF-SUPPLEMENTAL-MIB::cRfSupSysRunningConfigSyncTime

OID (numeric): 1.3.6.1.4.1.9.9.198.1.1.4

Node type: OBJECT-TYPE

Type: DateAndTime

Access: read-only

Description: The date and time when the running configuration was last successfully synced from the current Active unit to the Standby unit.

This object will remain uninstantiated if no sync has yet taken place since the current Active CPU was initialized or if a Standby unit was forced to take over before the initial database sync was completed.

Since automatic running configuration syncs are event driven and can be disabled by configuration, this time doesn't directly indicate whether Standby software reflects the running configuration of the Active unit.

Instead, see the cRfSupSysRunningConfigOper object to determine whether Standby running configuration is in sync with the Active CPU.

What is cRfSupSysRunningConfigSyncTime?

Reports the date and time the running configuration was last successfully synchronized from the active unit to the standby unit, confirming config replication is up to date.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.198.1.1.4
snmpwalk -v2c -c public <target> CISCO-RF-SUPPLEMENTAL-MIB::cRfSupSysRunningConfigSyncTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.198.1.1.4.1
snmpget -v2c -c public <target> CISCO-RF-SUPPLEMENTAL-MIB::cRfSupSysRunningConfigSyncTime.1

Start monitoring Cisco router/Catalyst switch with redundant supervisors/RP with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-RF-SUPPLEMENTAL-MIB::cRfSupSysRunningConfigSyncTime OID value, configure state conditions and alerts, and monitor any Cisco router/Catalyst switch with redundant supervisors/RP from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.198ciscoRfSupMIBCISCO-RF-SUPPLEMENTAL-MIB
1.3.6.1.4.1.9.9.198.1ciscoRfSupMIBObjectsCISCO-RF-SUPPLEMENTAL-MIB
1.3.6.1.4.1.9.9.198.1.1cRfSupSystemCISCO-RF-SUPPLEMENTAL-MIB
1.3.6.1.4.1.9.9.198.1.1.4cRfSupSysRunningConfigSyncTimeCISCO-RF-SUPPLEMENTAL-MIB