CISCO-OPTICAL-MIB :: coiOpticalControllerLaserStatus

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-OPTICAL-MIBcoiOpticalControllerLaserStatus

coiOpticalControllerLaserStatus

Module: CISCO-OPTICAL-MIB

OID (symbolic): CISCO-OPTICAL-MIB::coiOpticalControllerLaserStatus

OID (numeric): 1.3.6.1.4.1.9.9.828.1.1.2.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This object gives the current operational state of the Laser. Valid values are - 'up' - The laser is operational. 'down' - The laser is not operational.

What is coiOpticalControllerLaserStatus?

Read-only indicator of whether the laser on an optical controller is operationally up or down.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.828.1.1.2.1.2
snmpwalk -v2c -c public <target> CISCO-OPTICAL-MIB::coiOpticalControllerLaserStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.828.1.1.2.1.2.1
snmpget -v2c -c public <target> CISCO-OPTICAL-MIB::coiOpticalControllerLaserStatus.1

Start monitoring Cisco optical-interface equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-OPTICAL-MIB::coiOpticalControllerLaserStatus OID value, configure state conditions and alerts, and monitor any Cisco optical-interface equipment from a single console.

How to Use in IPNetwork Monitor

Select a Cisco optical-interface equipment as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type coiOpticalControllerLaserStatus into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This object gives the current operational state of the Laser. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'up', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.828ciscoOpticalMIBCISCO-OPTICAL-MIB
1.3.6.1.4.1.9.9.828.1ciscoOpticalMIBObjectsCISCO-OPTICAL-MIB
1.3.6.1.4.1.9.9.828.1.1coiOpticalControllerCISCO-OPTICAL-MIB
1.3.6.1.4.1.9.9.828.1.1.2coiOpticalControllerTableCISCO-OPTICAL-MIB
1.3.6.1.4.1.9.9.828.1.1.2.1coiOpticalControllerEntryCISCO-OPTICAL-MIB
1.3.6.1.4.1.9.9.828.1.1.2.1.2coiOpticalControllerLaserStatusCISCO-OPTICAL-MIB