CISCO-ITP-MSU-RATES-MIB :: cimrMsuProcTable

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-ITP-MSU-RATES-MIB › cimrMsuProcTable

cimrMsuProcTable

Module: CISCO-ITP-MSU-RATES-MIB

OID (symbolic): CISCO-ITP-MSU-RATES-MIB::cimrMsuProcTable

OID (numeric): 1.3.6.1.4.1.9.9.529.1.2.1

Node type: OBJECT-TYPE

Access: not-accessible

Description: This table provides information associated with each
processor.  Thresholds are provided to control the 
behavior of the following objects from the 
cimrMsuTrafficTable table.

-- cimrMsuTrafficRateState          
-- cimrMsuTrafficRate               
-- cimrMsuTrafficSize                
-- cimrMsuProcDurWarning         
-- cimrMsuProcDurOverloaded       

Any changes to these thresholds will cause a reset of
measurements which is indicated by cimrMsuProcReset
and cimrMsuProcResetTimestamp objects.

Notifications thresholds.
In order to generate notifications when MSU rate switch
states the customer must define traffic levels using the
following objects.  When the global objects contain 
non-zero values they will act as defaults to all entries 
in table.  

global:
- cimrMsuRateAcceptableThreshold 
- cimrMsuRateWarningThreshold    
- cimrMsuRateOverloadedThreshold 

Per processor: 
- cimrMsuProcAcceptableThreshold 
- cimrMsuProcWarningThreshold    
- cimrMsuProcOverloadedThreshold

The global thresholds only apply when all of the threshold
objects at instance level are set to zero.  Set operations 
against thresholds must be performed as single operation.

Calculation of cimrMsuTrafficRateState object is performed in 
the following manner to only report significant changes
in traffic.  In order to switch to a higher state the 
traffic rate must equal or exceed the next higher 
threshold.  For example when current state is acceptable
the traffic must equal or exceed value specified by 
warning-threshold to obtain warning state.  In order to
switch to a lower state the traffic rate must be less than
the next lower threshold.  For example when current state 
is overloaded the traffic must drop below warning-threshold
to obtain warning state.

Example:
Acceptable-Threshold = 2000
Warning-Threshold    = 2500
Overloaded-Threshold = 3000

Sample  Rate  Old State     New State
------  ----  ----------    ----------
     1  2000  Acceptable    Acceptable
     2  2500  Acceptable    Warning
     3  2200  Warning       Warning
     4  2000  Warning       Acceptable
     5  3000  Acceptable    Overloaded
     5  1000  Overloaded    Acceptable

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.529ciscoItpMsuRatesMIBCISCO-ITP-MSU-RATES-MIB
1.3.6.1.4.1.9.9.529.1ciscoItpMsuRatesMIBObjectsCISCO-ITP-MSU-RATES-MIB
1.3.6.1.4.1.9.9.529.1.2cimrTablesCISCO-ITP-MSU-RATES-MIB
1.3.6.1.4.1.9.9.529.1.2.1cimrMsuProcTableCISCO-ITP-MSU-RATES-MIB