All MIBs › CISCO-IF-MONITOR-NOTIF-MIB › cIfMonNotifSeverity
cIfMonNotifSeverity
Module: CISCO-IF-MONITOR-NOTIF-MIB
OID (symbolic): CISCO-IF-MONITOR-NOTIF-MIB::cIfMonNotifSeverity
OID (numeric): 1.3.6.1.4.1.9.10.999.1.2.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The severity of the condition on the link when the notification is sent. A smaller enumerated integer value indicates that the exceeded condition is more severe.
When a red severity notification is sent, it signifies that a severe event has occured, in which certain errors over an interval have reached/exceeded a high threshold .
When a yellow severity notification is sent it signifies that an event has occured, in which certain errors over an interval have reached/exceeded a low threshold.
What is cIfMonNotifSeverity?
Indicates the severity level of the link condition that triggered a notification, with lower values representing more severe conditions.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.10.999.1.2.1.2 snmpwalk -v2c -c public <target> CISCO-IF-MONITOR-NOTIF-MIB::cIfMonNotifSeverity
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.10.999.1.2.1.2.1 snmpget -v2c -c public <target> CISCO-IF-MONITOR-NOTIF-MIB::cIfMonNotifSeverity.1
Start monitoring Cisco routers and switches (interface error thresholds) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-IF-MONITOR-NOTIF-MIB::cIfMonNotifSeverity OID value, configure state conditions and alerts, and monitor any Cisco routers and switches (interface error thresholds) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.10 | ciscoExperiment | CISCO-SMI |
| 1.3.6.1.4.1.9.10.999 | ciscoCableDsgIfMIB | CISCO-CABLE-DSG-IF-MIB |
| 1.3.6.1.4.1.9.10.999.1 | ccdsgIfCaVendor | CISCO-CABLE-DSG-IF-MIB |
| 1.3.6.1.4.1.9.10.999.1.2 | cVrrpNotificationCntl | CISCO-IETF-VRRP-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.10.999.1.2.1 | cIfMonNotifEntry | CISCO-IF-MONITOR-NOTIF-MIB |
| 1.3.6.1.4.1.9.10.999.1.2.1.2 | cIfMonNotifSeverity | CISCO-IF-MONITOR-NOTIF-MIB |